Download Instruction manual gapCONTROL setup software - Micro

Transcript
Description of the Measuring Programs
4.1.1
"Edge Points Gap" Measuring Program
Use the "Edge Points Gap" measuring program to determine the characteristics of a simple gap based on
the inner edge points.
The program first determines the largest gap in the profile (the so-called "base gap"). Starting from the
base gap, the start and end points of the gap in the left and right sections of the profile are determinated
as follows:
-
Start point: The last point of the left profile section.
End point: The first point of the right profile section.
Afterwards, the flushness is measured using the selected algorithm (see Chapter 3.13.8).
Proceed as follows:
Configure the gapCONTROL measuring system ("Scanner settings" input field, see Chapter 3.7).
If necessary, limit the measuring range in order to eliminate any interference points (see Chapter 3.13.1).
Set the minimum width and alignment of the gap (see Chapter 3.13.4).
Set the algorithm for determining the flushness (see Chapter 3.13.8).
If necessary, activate dynamic tracking of the ranges for cutting out and line fitting (see Chapter 3.13.10).
A
D
E
C
B
1
G
H
F
Fig. 4.2: "Edge Points Gap" measuring program
Display elements and parameters in the "Edge Points Gap" measuring program:
A
"General" toolbar: Using this toolbar, you can select the data source (see Chapter 3.5), save profile
sequences (see Chapter 3.6), save and load parameters (see Chapter 3.13.13) and reset the
selected parameters to the default settings (see Chapter 3.13.16).
B
Scanner settings: Change the settings of gapCONTROL with these values (see Chapter 3.7). In offline mode (see Chapter 3.5), this input field is replaced by the "File settings" input field, which enables you to control the playback process of a profile sequence loaded from a file (see Chapter 3.10).
Page 69