Download MAGIC 3.2.0 Help MANUAL

Transcript
Part I - Using MAGIC
Chapter 2 - Creating the Simulation Input File
Table of Electro-static Fields Used in Diagnostics of the POISSON Solution in MAGIC2D
E1ST
E1st
HFF
F
x1 component of electro-static field
E2ST
E2st
FHF
F
x2 component of electro-static field
PHST
PHst
FFF
F
Scalar Potential field
The electro-static solution fields are generally normalized from the potential, PHST. These may then be applied with the
CIRCUIT command (MAGIC2D only) to enforce a specific relative potential difference between electrodes. The use
of the POISSON and CIRCUIT command are recommend only in cases where the 2d geometry prohibits the injection of
the potential fields through the use of a port boundary. The mixture of PORT boundaries with the POISSON and
CIRCUIT command is discouraged, but not prohibited. Careful consideration should be given to the implications of
mixing these two typed of field insertion.
Table of Particle Force Fields Used in Diagnostics
B1ST
B1st
FFF
F
x1 component of static magnetic field
B2ST
B2st
FFF
F
x2 component of static magnetic field
B3ST
B3st
FFF
F
x3 component of static magnetic field
|BST|
|Bst|
FFF
F
Magnitude of static magnetic field
E1AV
E1av
FFF
F
x1 component of the electric field used in Lorentz
E2AV
E2av
FFF
F
x2 component of the electric field used in Lorentz
E3AV
E3av
FFF
F
x3 component of the electric field used in Lorentz
|EAV|
|Eav|
FFF
F
Magnitude of the electric field used in Lorentz
B1AV
B1av
FFF
F
x1 component of the magnetic field used in Lorentz
B2AV
B2av
FFF
F
x2 component of the magnetic field used in Lorentz
B3AV
B3av
FFF
F
x3 component of the magnetic field used in Lorentz
|BAV|
|Bav|
FFF
F
Magnitude of the magnetic field used in Lorentz
DIELECTRIC
Table of Fields Used in Diagnostics of Property Values.
εr
HHH
F
Relative Permittivity
Magic3d
DIELECTRIC1
εr1
HHH
F
Relative Permittivity x1
Magic2d
DIELECTRIC2
εr2
HHH
F
Relative Permittivity x2
Magic2d
DIELECTRIC3
εr3
HHH
F
Relative Permittivity x3
Magic2d
IDIELECTRIC1
1/εr1
HFF
F
Inverse Relative Permittivity x1
Magic2d
IDIELECTRIC2
1/εr2
FFH
F
Inverse Relative Permittivity x2
Magic2d
IDIELECTRIC3
1/εr3
FHH
F
Inverse Relative Permittivity x3
Magic2d
SIGMAE
σE
HHH
F
Electrical conductivity
Both
SIGMAB
σB
HHH
F
Magnetic conductivity
Both
Table of Fields Used in Diagnostics of Gas Conductivity Model.
MAGIC User’s Manual
2-8