Download Applications Engineering Manual - Chilled

Transcript
System Controls
variable-speed drive on one or more of the condenser fans. This is typically
an option available from the chiller manufacturer.
For a water-cooled chiller, the condenser-water system may need to be
designed to vary either the temperature or flow rate of the water through the
condenser. For example, consider an office building that has been
unoccupied during a cool autumn weekend, during which time the
temperature of the water in the cooling tower sump has dropped to 40°F
(4°C). Monday is sunny and warm, and the building cooling load requires a
chiller to be started. Pumping this cold water through the chiller condenser
results in a very low refrigerant pressure inside the condenser. Because the
chiller is operating at part load and the tower sump is relatively large, the
minimum pressure difference may not be reached before the chiller is turned
off on a safety.
The solution is to either increase the temperature of the water entering the
condenser or decrease the flow rate of water through the condenser. Both of
these strategies will increase the temperature and pressure of the refrigerant
inside the condenser. After the minimum pressure difference is reached,
system operation may return to normal.
Common approaches for increasing the evaporator-to-condenser pressure
difference include:
For more information on condensing
pressure control for water-cooled
chillers, refer to the Trane engineering
bulletins titled “Condenser Water
Temperature Control For CenTraVac®
Centrifugal Chiller Systems” (CTVPRB006-EN) and “Water-Cooled Series
R® Chiller - Models RTHB & RTHD:
Condenser Water Control” (RLC-PRB017EN).
•
Cycling or varying the speed of cooling tower fans to increase the
temperature of water leaving the cooling tower
•
Modulating a throttling valve to reduce the flow rate of water through the
condenser
•
Using a chiller condenser bypass pipe to reduce the flow rate of water
through the condenser (Figure 136)
•
Using a cooling tower bypass pipe to mix warm water leaving the
condenser with the cold tower water, thus increasing the temperature of
water entering the condenser
•
Using a variable-speed drive on the condenser water pump to reduce the
water flow rate through the condenser
Each of these strategies has its advantages and disadvantages. Selecting the
appropriate condensing pressure control scheme will depend on the specific
requirements of the application.
SYS-APM008-EN
Chilled-Water VAV Systems
189