System Controls variable-speed drive on one or more of the condenser fans. This is typically an option available from the chiller manufacturer. For a water-cooled chiller, the condenser-water system may need to be designed to vary either the temperature or flow rate of the water through the condenser. For example, consider an office building that has been unoccupied during a cool autumn weekend, during which time the temperature of the water in the cooling tower sump has dropped to 40°F (4°C). Monday is sunny and warm, and the building cooling load requires a chiller to be started. Pumping this cold water through the chiller condenser results in a very low refrigerant pressure inside the condenser. Because the chiller is operating at part load and the tower sump is relatively large, the minimum pressure difference may not be reached before the chiller is turned off on a safety. The solution is to either increase the temperature of the water entering the condenser or decrease the flow rate of water through the condenser. Both of these strategies will increase the temperature and pressure of the refrigerant inside the condenser. After the minimum pressure difference is reached, system operation may return to normal. Common approaches for increasing the evaporator-to-condenser pressure difference include: For more information on condensing pressure control for water-cooled chillers, refer to the Trane engineering bulletins titled “Condenser Water Temperature Control For CenTraVac® Centrifugal Chiller Systems” (CTVPRB006-EN) and “Water-Cooled Series R® Chiller - Models RTHB & RTHD: Condenser Water Control” (RLC-PRB017EN). • Cycling or varying the speed of cooling tower fans to increase the temperature of water leaving the cooling tower • Modulating a throttling valve to reduce the flow rate of water through the condenser • Using a chiller condenser bypass pipe to reduce the flow rate of water through the condenser (Figure 136) • Using a cooling tower bypass pipe to mix warm water leaving the condenser with the cold tower water, thus increasing the temperature of water entering the condenser • Using a variable-speed drive on the condenser water pump to reduce the water flow rate through the condenser Each of these strategies has its advantages and disadvantages. Selecting the appropriate condensing pressure control scheme will depend on the specific requirements of the application. SYS-APM008-EN Chilled-Water VAV Systems 189