3. Installation
Brief description of the I/O signals at the Control connection
A detailed description of the I/O signals can be found in section 4.4.
3-24
Output
Pin
Manual
O1: P.01
13
O2: P.02
12
O3: P.03
11
Supplies a 1-signal when the
d i iis iin th
drive
the appropriate
i t
p
pp
g for
position. Supplies
a 1-signal
50 ms when the drive overruns
the relevant position.
O4: P.04
10
O5: Error
9
Supplies a 1-signal when there
is an error.
Input
Pin
Manual
I1: P.01
8
I2: P.02
7
I3: P.03
6
1-signal (min. 20 ms) sends
command
d to
t move to
t the
th rell
evant p
position when there is a
0-signal at the other inputs P.0...
I4: P.04
5
I7: +/}
4
I6: Enter/Teach/Esc
3
I5: {/–
2
I8: Remote
1
Controls the drive when there is
a 1-signal
1 ig l att th
the Remote
R
t iinput
ut
((see Appendix
pp
)
A).
A 1-signal deactivates the operating keys and activates the relevant Remote inputs (pins 2...4).
Festo P.BE-SPC11-SYS-EN en 0012NH