Chapter 5: Configuration Decoded (Intermec ISCP) Set Length L1, Set Length L2, And Set Length L3 Lengths for “Codabar” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length. Field Size/Chars Refer to page 148 for details. 5.11.4.17 2D PDF-417 Enabled Set this parameter to on to enable “2D PDF-417”. Field Size/Chars Refer to page 148 for details. 5.11.4.18 2D Micro PDF-417 Enabled Set this parameter to ON to enable “2D Micro PDF-417”. Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes: ]C1 if the first codeword is 903-907, 912, 914, 915 ]C2 if the first codeword is 908 or 909 ]C0 if the first codeword is 910 or 911 If Code 128 Emulation is set to OFF, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 if the first codeword is 903-907, 912, 914, 915 Psion Teklogix 7530 G2 Hand-Held Computer User Manual 185