Download MF624 User`s Manual
Transcript
Programming Guide IRCCTRL Bit BADR2+0x6C IRC Conrol Register Description W Default IR C 0M O D E. Selects IR C 0 counter operation. 00: IR C , 4 edge detection 1:0 01: bidirectional counter, rising edge 0 10: bidirectional counter, falling edge 11: bidirectional counter, either edge IR C 0C O UN T. IRC 0 count control. 00: IR C 0 count enabled 3:2 01: IR C 0 count disabled 0 10: IRC 0 count enabled if I0 input is 0 11: IRC 0 count enabled if I0 input is 1 IR C 0R E SE T. IRC 0 reset control. 000: IR C 0 reset disabled 001: IR C 0 reset 010: IRC 0 reset if I0 is 0 6:4 011: IRC 0 reset if I0 is 1 0 100: IR C 0 reset by rising edge of I0 101: IR C 0 reset by falling edge of I0 110: IR C 0 reset by either edge of I0 111: R eserved 7 9:8 IR C 0FIL T E R. IR C 0 digital filter control. 1 enables digital filter on IR C 0 inputs. 0 disables filtering. IR C 1M O D E. Selects IR C 1 counter operation. See IR C0M O D E 11:10 IR C 1C O UN T. IR C 1 count control. 14:12 IR C 1R E SE T. IRC 1 reset control. 15 17:16 See IRC0COUNT See IRC0RESET IR C 1FIL T E R. IR C 1 digital filter control. 1 enables digital filter on IR C 1 inputs. 0 disables filtering. IR C 2M O D E. Selects IR C 2 counter operation. See IR C0M O D E 19:18 IR C 2C O UN T. IR C 2 count control. 22:20 IR C 2R E SE T. IRC 2 reset control. See IRC0COUNT See IRC0RESET 0 0 0 0 0 0 0 0 23