IEC 60335-2-80
Clause
Requirement - Test
Verdict
Tilting test through an angle of 10° (appliance placed
on an inclined plane/horizontal plane); appliance
does not overturn
N/A
Tilting test repeated on appliances with heating
elements, angle of inclination increased to 15°
N/A
Possible heating test in overturned position;
temperature rise does not exceed values shown in
table 9
N/A
Portable pedestal fans exceeding 1,7 m and
exceeding 10 kg tested with a force of 40 N at 1,5 m
(IEC 60335-2-80)
20.2
Result - Remark
N/A
No such fans.
Moving parts adequately arranged or enclosed as to
provide protection against personal injury
P
Protective enclosures, guards and similar parts are
non-detachable
P
Adequate mechanical strength and fixing of
protective enclosures
P
Self-resetting thermal cut-outs and overcurrent
protective devices not causing a hazard, by
unexpected reclosure
N/A
No such cut-outs.
Not possible to touch dangerous moving parts with
test probe
P
20.101
Fan blades, other than those for mounting at high
level, shall be guarded, unless
(IEC 60335-2-80)
21
MECHANICAL STRENGTH
P
21.1
Appliance has adequate mechanical strength and is
constructed as to withstand rough handling
P
Checked by applying blows to the appliance in
accordance with test Ehb of IEC 60068-2-75, spring
hammer test, impact energy 0,5 J
P
If necessary, supplementary or reinforced insulation
subjected to the electric strength test of 16.3
N/A
If necessary, repetition of groups of three blows on a
new sample
N/A
Accessible parts of solid insulation having strength to
prevent penetration by sharp implements
P
21.2
The insulation is tested as specified, unless
the thickness of supplementary insulation is at least 1
mm and reinforced insulation is at least 2 mm
TRF No. IEC60335_2_80B_mod
Blades are guarded after the
installation according the
User’s Manual by the duct
P
N/A
P
TRF originator: KEMA