Download ACCON-AGLink 4.0

Transcript
Programming reference additional functions
11.4
Function reference converting S7 types
11.4.1
Converting S7 string into string (AGL_S7String2String)
With this function you can convert a byte buffer, which content is a S7 string, into a
string. The current length is considered here.
Note:
Alternatively, VB programers should look for the function AGL_S7String2VBString in
chapter 12 Additional functions for VB respectively VBA.
C/C++-Syntax:
int WINAPI AGL_S7String2String( PBYTE S7String, LPSTR Text, int
MaxChars );
Visual Basic-Syntax:
Declare Function AGL_S7String2String Lib "AGLink40.DLL" (ByRef
S7String As Byte, ByVal Text As String, ByVal MaxChars As Long) As
Long
Delphi-Syntax:
function AGL_S7String2String( var S7String: Byte; Text: PChar;
MaxChars: Integer ): Integer; stdcall;
Parameter:
S7String
Indicator on byte buffer in S7 string format
Text
Indicator on string
MaxChars
Number of maximum characters which has to be copied
Return value:
AGL40_SUCCESS
If all worked properly
<0
Error number (s. AGL_Defines.H,
AGL_Defines.BAS or AGLink40.PAS)
ACCON-AGLink 4.0
261
DELTALOGIC GmbH