Download AutoCalTM
Transcript
Two-Way Loudspeaker Functional Blocks All audio enters audio input stage where all crossover and filtering takes place. The audio outputs go via digital-to-analog conversion to built-in power amplifiers and on to the tweeter and woofer drivers. The loudspeakers have built-in user interfaces with switches and a rotary level control on the front of the loudspeaker. Subwoofer (SE7261A) Digital Audio Input The digital input has a fixed sensitivity. Digital signals are represented relative to their maximum or Full Scale value. For example, -10 dBFS means that the signal level is 10 dB below the full scale or the maximum representable digital signal. In Genelec SE7261A subwoofers, the maximum audio level of 0 dBFS translates to the theoretical 115 dB SPL at 1 m sound pressure level. For example, a -36 dBFS signal produces a sound level of 79 dB SPL at 1 m. Genelec Loudspeaker Manager GLM.SE™ adjusts the monitoring volume down from this level. Digital audio sample rates can vary from 32 kHz to 192 kHz and word length from 16 to 24 bits. SingleWire formats are only supported. Note that there may be a valid AES/EBU signal although the signal is silent. 16