Download AN420 - Simple Sensor Application Kit
Transcript
DS18S20_Read float DS18S20_Read (int UnitNbr, int Units, float *Degrees); FUNCTION DESCRIPTION Reads the temperature value of the specified DS18S20. The device must have already been sent the convert command and the required delay time (750 ms) must be completed. PARAMETERS UnitNbr unit number of the desired DS18S20. If the unit number is -1, then use the Skip ROM command. This is valid if there is only a single 1-Wire device on the bus. Units OW_OPT_DEGC = degrees C OW_OPT_DEGF = degrees F Degrees address to place floating result. RETURN VALUE OW_ERR_SUCCESS = success. OW_ERR_INVALID_UNIT = illegal unit number. OW_ERR_INVAlID_CRC = invalid CRC. SEE ALSO OWInit, OWSearchROM, DS18S20_Init 022-0141 Rev. B 21