Download Operating Manual
Transcript
Glossary Angular velocity, w — Rate of rotation, measured in radians per second 2π rpm ω = ----------------60 or w = 0.10472 rpm Anodized coating — A thin, hard layer of aluminum oxide formed electrochemically on aluminum rotor and/or accessory surfaces as a protective coating for corrosion resistance Autoclaving — Sterilization by heat (dry or steam) Buoyant density — The density of a particle in a specified liquid medium Buna N — Black nitrile rubber used for O-rings and gaskets in rotor assemblies; should be used at temperatures between –34 and 121°C (–30 and 250°F) Clearing time, t — t = k/s, where t is time in hours, k is the clearing factor of the rotor, and s is the sedimentation coefficient in Svedberg units (S) CsCl — Cesium chloride; a high-density salt used in solution in isopycnic separations to separate particles based on their density CsS0 — Cesium sulfate; a salt, similar to CsCl, that will form its own gradient in solution Delrin — Thermoplastic material (acetal homopolymer) used for most tube adapters (Delrin is a registered trademark of E.I. Du Pont de Nemours & Company.) Density — Mass per unit volume Density separation — A centrifugal separation process based on differences in particle densities Differential separation — A centrifugal separation process based on differences in particle sizes Centrifugal effect — Accumulated value of: t2 ∫ ω 2 dt t1 where t is time and w is angular velocity Centrifugal force — In a centrifugal field, the force which causes a particle to move away from the center of rotation Clearing factor k — Calculated for all Beckman Coulter high-speed rotors as a measure of the rotor’s relative pelleting efficiency: ln ( rmax ⁄ rmin ) 10 13 - × -----------k = ---------------------------------3600 ω2 or EPDM — Ethylene propylene rubber used for O-rings and pad adapters; should be used at temperatures between –57 and 120°C (–70 and 250°F) Ethidium bromide — A fluorescent intercalating orange dye used commonly in the separation of DNA and in gel electrophoresis Fixed-angle rotor — A rotor in which the tubes are held at an angle (usually 20 to 45 degrees) from the axis of rotation g-Max — A system of centrifugation using a combination of short Quick-Seal tubes and floating spacers, designed to reduce volumes while maximizing separation efficiency HDPE — High density polyethylene used for adapters 253303 × ln ( rmax ⁄ rmin ) k = -----------------------------------------------------------(RPM / 1000) 2 LR-IM-24AC Glossary-1