Download Operating Manual

Transcript
Glossary
Angular velocity, w — Rate of rotation, measured
in radians per second
2π rpm
ω = ----------------60
or
w = 0.10472 rpm
Anodized coating — A thin, hard layer of
aluminum oxide formed electrochemically on
aluminum rotor and/or accessory surfaces as a
protective coating for corrosion resistance
Autoclaving — Sterilization by heat (dry or steam)
Buoyant density — The density of a particle in a
specified liquid medium
Buna N — Black nitrile rubber used for O-rings and
gaskets in rotor assemblies; should be used at
temperatures between –34 and 121°C (–30 and
250°F)
Clearing time, t — t = k/s, where t is time in hours,
k is the clearing factor of the rotor, and s is the
sedimentation coefficient in Svedberg units (S)
CsCl — Cesium chloride; a high-density salt used in
solution in isopycnic separations to separate
particles based on their density
CsS0 — Cesium sulfate; a salt, similar to CsCl, that
will form its own gradient in solution
Delrin — Thermoplastic material (acetal
homopolymer) used for most tube adapters
(Delrin is a registered trademark of E.I. Du Pont
de Nemours & Company.)
Density — Mass per unit volume
Density separation — A centrifugal separation
process based on differences in particle densities
Differential separation — A centrifugal
separation process based on differences in
particle sizes
Centrifugal effect — Accumulated value of:
t2
∫ ω 2 dt
t1
where t is time and w is angular velocity
Centrifugal force — In a centrifugal field, the
force which causes a particle to move away from
the center of rotation
Clearing factor k — Calculated for all
Beckman Coulter high-speed rotors as a
measure of the rotor’s relative pelleting
efficiency:
ln ( rmax ⁄ rmin ) 10 13
- × -----------k = ---------------------------------3600
ω2
or
EPDM — Ethylene propylene rubber used for
O-rings and pad adapters; should be used at
temperatures between –57 and 120°C (–70 and
250°F)
Ethidium bromide — A fluorescent intercalating
orange dye used commonly in the separation of
DNA and in gel electrophoresis
Fixed-angle rotor — A rotor in which the tubes are
held at an angle (usually 20 to 45 degrees) from
the axis of rotation
g-Max — A system of centrifugation using a
combination of short Quick-Seal tubes and
floating spacers, designed to reduce volumes
while maximizing separation efficiency
HDPE — High density polyethylene used for
adapters
253303 × ln ( rmax ⁄ rmin )
k = -----------------------------------------------------------(RPM / 1000) 2
LR-IM-24AC
Glossary-1