Download Errata Sheet

Transcript
Errata Sheet
XC167CI-32F, (E)ES-BB, BB
History List/Change Summary
1
History List/Change Summary
(from step (E)ES-BA, previous errata sheet: V1.0, step: (E)ES-BB, BB)
Table 1
Functional Deviations
Functional
Problem
Short Description
Fixed Change
in step
EBC_X.003
TwinCAN access with EBC enabled
EBC_X.006
Visibility of internal LXBus cycles on external
address bus
CPU_X.002
Branch to wrong target after mispredicted JMPI
CPU_X.003
Software Modification of Return Address on
System Stack in combination with
RET/RETP/RETS instructions
new
INT_X.007
Interrupt using a Local Register Bank during
execution of IDLE
update
INT_X.008
HW Trap during Context Switch in Routine using
a Local Bank
new
INT_X.009
Delayed Interrupt Service of Requests using a
Global Bank
new
PORTS_X.012.1
Interference of Input Signals on P0H.6 and P3.6
with internal Flash
new
SCU_X.010
Reset while PLL is not locked - step (E)ES-BA
only
SCU_X.011
Register Security Mechanism after Write Access
in Secured Mode (replaces SCU_X.D7)
ES+BA
BA
TwinCAN_AI.007 Transmit after error
(former name: TwinCAN2.007/TwinCAN_X.007)
TwinCAN_AI.008 Double remote request
(former name: TwinCAN2.008/TwinCAN_X.008)
TwinCAN_AI.009 CPUUPD remote
(former name: TwinCAN2.009/TwinCAN_X.009)
TwinCAN_AI.010 Reserved Bits in Register MSGARHn[15:13]
FLASH_X.004
PACER trap after wake-up from Sleep/Idle mode
ASC_X.001
ASC Autobaud Detection in 8-bit Modes with
Parity
Errata Sheet
2/49
V1.1, 2007-06-21