Download 2.4 AC112 - ETHERNET Powerlink Interface
Transcript
Technical Data • ACOPOS Plug-in Modules Product ID 8AC112.60-1 Powerlink Interface Connection, Module Side 2 x RJ45 socket Indications Status LEDs Electrical Isolation ETHERNET - ACOPOS Yes 100 m 1) Maximum Distance per Segment 100 Mbit/s Network Capable Yes Hub, 2x Yes Maximum Number of Hub Levels Chapter 2 Technical Data Baud Rate 10; see section 2 "ACOPOS™ Configurations" on Page 22 Cabling Topology Star or tree with level 2 hubs Possible Station Operating Modes Synchronous to Powerlink cycle Watchdog Function Hardware Software Yes (via ACOPOS servo drive) Yes (via ACOPOS servo drive) Operational Conditions Environmental Temperature During Operation 0 to +50 °C Relative Humidity During Operation 5 to 95%, non-condensing Storage and Transport Conditions Storage Temperature -25 to +55 °C Relative Humidity During Storage 5 to 95%, non-condensing Transport Temperature -25 to +70° C Relative Humidity During Transport 95 % at +40 °C Table 22: Technical data for AC112 (Forts.) 1) With a cycle time of 400 µs and 10 ACOPOS servo drives, the maximum total cable length is 200 m. 2.4.4 Powerlink Station Number Settings The Powerlink station number can be set using two HEX code switches: Image Code switch Powerlink station number n 16s position (high) o 1s position (low) The Powerlink station number change takes effect the next time the ACOPOS servo drive is switched on. Information: In principle, station numbers between $01 and $FD are permitted. However, station numbers between $F0 and $FD are reserved for future system expansions. For reasons of compatibility, we recommend avoiding these station numbers. Station numbers $00, $FE and $FF are reserved and are therefore not allowed to be set. Table 23: Setting the Powerlink station number ACOPOS User's Manual V 1.3.1 59