Product ID
8AC112.60-1
Powerlink Interface
Connection, Module Side
2 x RJ45 socket
Indications
Status LEDs
Electrical Isolation
ETHERNET - ACOPOS
Yes
100 m 1)
Maximum Distance per Segment
100 Mbit/s
Network Capable
Yes
Hub, 2x
Yes
Maximum Number of Hub Levels
Chapter 2
Technical Data
Baud Rate
10; see section 2 "ACOPOS™ Configurations" on Page 22
Cabling Topology
Star or tree with level 2 hubs
Possible Station Operating Modes
Synchronous to Powerlink cycle
Watchdog Function
Hardware
Software
Yes (via ACOPOS servo drive)
Yes (via ACOPOS servo drive)
Operational Conditions
Environmental Temperature During
Operation
0 to +50 °C
Relative Humidity During Operation
5 to 95%, non-condensing
Storage and Transport Conditions
Storage Temperature
-25 to +55 °C
Relative Humidity During Storage
5 to 95%, non-condensing
Transport Temperature
-25 to +70° C
Relative Humidity During Transport
95 % at +40 °C
Table 22: Technical data for AC112 (Forts.)
1) With a cycle time of 400 µs and 10 ACOPOS servo drives, the maximum total cable length is 200 m.
2.4.4 Powerlink Station Number Settings
The Powerlink station number can be set using two HEX code switches:
Image
Code switch
Powerlink station number
n
16s position (high)
o
1s position (low)
The Powerlink station number change takes effect the next time the ACOPOS servo drive is switched on.
Œ

Information:
In principle, station numbers between $01 and $FD are permitted.
However, station numbers between $F0 and $FD are reserved for future system expansions. For reasons
of compatibility, we recommend avoiding these station numbers.
Station numbers $00, $FE and $FF are reserved and are therefore not allowed to be set.
Table 23: Setting the Powerlink station number
ACOPOS User's Manual V 1.3.1
59