Download DUST FLOW - CMB Control
Transcript
PRODUCT DATA SHEET DT770T & DT270T Electrodynamic Features for Enhanced Measurement Dynatrack Instrument automatically adjusts it’s dynamic range to track fast moving dust pulses (typically found after reverse jet cleaning baghouses) to ensure good measurement AGC The instrument automatically adjusts its gain control to suit varying dust loading applications (no need for user to adjust gain controls or potentiometers) AZC Automatic Zero Compensation eliminates drift due to frequency driven signal processing Instrument Memory Capacity (Per Dust Channel) 24 hour memory Broken Bag † Average memory † Storage and averaging of long-term memory Rolling 24 hours at 30 second store rate Displays one complete cleaning cycle 16000 data points (e.g. 600 days @ 1 hour store rate) Adjustable over range of 1 minute to 8 hours Instrument Functions Monitoring units Calibration mode Review memory Channel name Access security Data security Broken bag mode mg/m3, g/m3, units or user defined Computes calibration factors associated with isokinetic sampling Graphics or listing display of stored data 24hr and †longterm averages 10 letter name (eg kiln stack) to identify stack 2 password levels protect unauthorised entry and instrument calibration Data stored in non-volatile memory Displays bag cleaning cycle in progress Instrument Inputs/Outputs Type Output (per channel) Output Output Output (per channel) Input Input (per channel) Input (per channel) Name Dust emissions Serial O/P Relay 1 Relay 2 Digital 1 Digital 2 Analogue Specification 4-20mA isolated (max 250Ω) RS-232 Single pole make rated 2A, 230V Single pole make rated 2A, 230V Digital (contact closure) Digital (contact closure) 4-20mA Function Scalable over full range of emissions Download of emissions data to PC (optional on-line) Emission Alarm 1/ Instrument Alarms Emission Alarm 2 Plant running signal Bag cleaning reference pulse Oxygen compensation (option) Control /Expansion Unit Control Module IP65 160w x 90d x 260 l 3kg Die-cast aluminium (epoxy-coated) 110Vac or 230Vac 50Hz / 60Hz 10VA 250mA Backlit LCD providing numerical and graphical display -25˚C to +55˚C 1 Enclosure rating Enclosure size (mm) Enclosure weight Enclosure material Power supply (switchable) Fuse rating Display type Temperature range (electronics) No. of dust channels Expansion Module IP65 160w x 90d x 360 l 4.5kg Die-cast aluminium (epoxy-coated) 110Vac or 230Vac 50Hz/60Hz 250mA N/A -25˚C to +55˚C Up to an additional 3 Instrument Specifications Resolution Response time Self checks <0.01mg/m3 <10 seconds for 95% change (user selectable) Automatic zero, span and probe short-circuit checks Sensors & Cables Sensor Types S I Temperature Range (flue gas) 250 400 800 No Air Purge (standard) Air Purge (optional) Stack/Duct Connection N AP 316 Stainless Steel Totally Insulated Sensor (PTFE or Ceramic) Up to 250°C (standard) Up to 400°C (optional) Up to 800°C (optional) Over 800°C consult factory /4“ BSP@0.5 litre/min 1 11/2” BSP (female) NPT option Stack Diameter (mm) Standard Probes for up to 3m Cross Stack Probes for up to 6m diameter stacks. Enclosure Weight 1.8kg Enclosure Temperature Rating -25°c to +70°c Enclosure Rating IP65 Sensor Enclosure Material Die-cast Aluminium (epoxy-coated) Cable from Sensor to control unit 8-core Screened Cable from Sensor to control unit 10m Standard: 300m max