PRODUCT DATA SHEET
DT770T & DT270T
Electrodynamic Features for Enhanced Measurement
Dynatrack
Instrument automatically adjusts it’s dynamic range to track fast moving dust pulses (typically found after reverse jet
cleaning baghouses) to ensure good measurement
AGC
The instrument automatically adjusts its gain control to suit varying dust loading applications (no need for user to
adjust gain controls or potentiometers)
AZC
Automatic Zero Compensation eliminates drift due to frequency driven signal processing
Instrument Memory Capacity (Per Dust Channel)
24 hour memory
Broken Bag
†
Average memory
†
Storage and averaging of long-term memory
Rolling 24 hours at 30 second store rate
Displays one complete cleaning cycle
16000 data points (e.g. 600 days @ 1 hour store rate)
Adjustable over range of 1 minute to 8 hours
Instrument Functions
Monitoring units
Calibration mode
Review memory
Channel name
Access security
Data security
Broken bag mode
mg/m3, g/m3, units or user defined
Computes calibration factors associated with isokinetic sampling
Graphics or listing display of stored data 24hr and †longterm averages
10 letter name (eg kiln stack) to identify stack
2 password levels protect unauthorised entry and instrument calibration
Data stored in non-volatile memory
Displays bag cleaning cycle in progress
Instrument Inputs/Outputs
Type
Output (per channel)
Output
Output
Output (per channel)
Input
Input (per channel)
Input (per channel)
Name
Dust emissions
Serial O/P
Relay 1
Relay 2
Digital 1
Digital 2
Analogue
Specification
4-20mA isolated (max 250Ω)
RS-232
Single pole make rated 2A, 230V
Single pole make rated 2A, 230V
Digital (contact closure)
Digital (contact closure)
4-20mA
Function
Scalable over full range of emissions
Download of emissions data to PC (optional on-line)
Emission Alarm 1/ Instrument Alarms
Emission Alarm 2
Plant running signal
Bag cleaning reference pulse
Oxygen compensation (option)
Control /Expansion Unit
Control Module
IP65
160w x 90d x 260 l
3kg
Die-cast aluminium (epoxy-coated)
110Vac or 230Vac 50Hz / 60Hz 10VA
250mA
Backlit LCD providing numerical
and graphical display
-25˚C to +55˚C
1
Enclosure rating
Enclosure size (mm)
Enclosure weight
Enclosure material
Power supply (switchable)
Fuse rating
Display type
Temperature range (electronics)
No. of dust channels
Expansion Module
IP65
160w x 90d x 360 l
4.5kg
Die-cast aluminium (epoxy-coated)
110Vac or 230Vac 50Hz/60Hz
250mA
N/A
-25˚C to +55˚C
Up to an additional 3
Instrument Specifications
Resolution
Response time
Self checks
<0.01mg/m3
<10 seconds for 95% change (user selectable)
Automatic zero, span and probe short-circuit checks
Sensors & Cables
Sensor Types
S
I
Temperature Range
(flue gas)
250
400
800
No Air Purge (standard)
Air Purge (optional)
Stack/Duct Connection
N
AP
316 Stainless Steel
Totally Insulated Sensor
(PTFE or Ceramic)
Up to 250°C (standard)
Up to 400°C (optional)
Up to 800°C (optional)
Over 800°C consult factory
/4“ BSP@0.5 litre/min
1
11/2” BSP (female) NPT option
Stack Diameter (mm)
Standard Probes for up to 3m
Cross Stack Probes for up
to 6m diameter stacks.
Enclosure Weight
1.8kg
Enclosure Temperature Rating -25°c to +70°c
Enclosure Rating
IP65
Sensor Enclosure Material
Die-cast Aluminium
(epoxy-coated)
Cable from Sensor to control unit 8-core Screened
Cable from Sensor to control unit 10m Standard: 300m max