DATA OUTPUT
Tertiary Antenna Saturation
PIC Health Error
FPGA Health Error
EEPROM Checksum Error
Sensor Reset since last R?
Direction Finder Error
Unused
Table 7: Status Flag Description
The antenna leakage fault is activated if the system suspects a leakage current, which diverts
the signal past the amplification stage. This may be caused by an insulation failure, so in the
event of this fault it is advisable to check the insulators are clean and free of any debris which
may allow the current on the antenna to pass directly to ground. Antenna saturation occurs
when current exceeding approximately 200nA is passed from the antenna to the amplifier for
at least a few seconds. This may occur as a result of an ungrounded charged object in contact
with the antenna.
The Second Status flag (NNN) is a 3 character decimal where individual bits have been set to
correspond to certain errors.
Flag
1
2
4
Description of error
Primary Antenna Fault
Secondary Antenna Fault
Tertiary Antenna Fault
Table 8: Second Status Flag Description
The antenna fault is activated when the unit detects an anomaly with the front end amplifier,
such as continuous saturation, which indicates the amplifier may have developed a fault or
been damaged and needs to be replaced.
The self test flags (MMMMM) are described in section 4.3.3.
4.7 Sensitivity Level Message
This message is transmitted in response to the LEVEL? Command – see section 7.12. The
threshold sensitivity ranges from 0 (most sensitive) to 10 (least sensitive).
LEVELS:,AA,BB,CC,DD,EE
Field
LEVELS:,
AA,
BB,
CC,
DD,
EE,
Description
Message Header
SNR Sensitivity Level (0-10)
P:S Ratio Sensitivity Level (0-10)
P:T Ratio Sensitivity Level (0-10)
Charged Precipitation Sensitivity Level (0-10)
Electric Field Sensitivity Level (0-10)
Table 9: Sensitivity Level Message
22
#Bytes
7
3
3
3
3
3