Download LOCAL OSCILLATOR MODULE
Transcript
Quick Start Guide Status The Status LEDs described in Table 2 display green when the module is functioning properly. A red LED indicated the module is not communicating with the PXI bus. Table 2 Soft Front Panel, LOM Control, Status LEDs Indicator Description +5Volts +5 V power supply displays green when functioning and is within tolerance. +12Volts +12 V power supply displays green when functioning and is within tolerance. +3Volts +3 V power supply displays green when functioning and is within tolerance. -12Volts -12 V power supply displays green when functioning and is within tolerance. Ref Detect Displays green when a reference signal is detected at REF IN on the front panel. Ref Lock Displays green when the internal reference is locked to the external reference signal applied at REF IN. Locked Displays green when the LO signal has settled and indicates that the final output is locked; this is an AND function of the three internal synthesizers (RBASE, VBASE, and DCELP). BUSY Displays green when the PXI Interface is BUSY writing commands to the internal hardware. No other commands should be sent to this PXI module while BUSY is active For factory use only. This number indicates the internal real-time ambient temperature of the module in degrees Celsius. 24 Phase Matrix PXI-1450B Local Oscillator Module