Download Proximity / PIN Access Controller
Transcript
Default Output Setting for Different Inputs [1] Reader#1 ID OK LV1 Door Relay (DR) 03 Alarm Relay (AR) 00 [2] Reader#1 ID OK LV2 05 [3] Reader#1 ID OK LV3 TTL#1 (T1) TTL#2 (T2) Buzzer (BZ) 00 00 00 00 00 00 00 05 00 00 00 00 [4] Reader#1 ID OK LV4 05 00 00 00 00 [5] Reader#1 ID Error 00 03 00 00 00 [6] Reader#1 T/S Error 00 03 00 00 00 [7] Reader#1 APB Error 00 03 00 00 00 [8] Reader#2 ID OK LV1 03 00 00 00 00 [9] Reader#2 ID OK LV2 05 00 00 00 00 [10] Reader#2 ID OK LV3 05 00 00 00 00 [11] Reader#2 ID OK LV4 05 00 00 00 00 [12] Reader#2 ID Error 00 03 00 00 00 [13] Reader#2 T/S Error 00 03 00 00 00 [14] Reader#2 APB Error 00 03 00 00 00 OUTPUT 12.6.1 Output Setting for Reader#1 ID OK Level 1 9 You can program the Output Activation Time, the length of time during which the output is activated after the EXIT button is pressed. The actual Output Activation Time equals either V seconds, provided that the Time Unit is set to 1 second, or V/10 seconds, provided that the Time Unit is set to 0.1 second. (V=Activation Time Value assigned for each output.) 9 You can set the time somewhere between 00 and 98 seconds (between 0.0 and 9.8 seconds if the Time Unit is set to 0.1 sec.) If you enter “99”, the corresponding output will be activated forever until you reset the Output. z z z z z DR: Door Relay Output AR: Alarm Relay Output T1: TTL#1 Output T2: TTL#2 Output BZ: Buzzer Output 53