Download 2 - Igor Chudov
Transcript
1305 Parameter List Parameter Group Metering Set Up Advanced Setup Frequency Set 18 Parameter Name Output Current Output Voltage Output Power DC Bus Voltage No. 54 1 23 53 Units 0.01 Amps 1 Volt 0.01 kW 1 Volt Minimum 0.00 0 0.00 0 Output Freq Freq Command MOP Hertz Drive Temp Last Fault % Output Power % Output Curr Input Mode Freq Select 1 Accel Time 1 Decel Time 1 Base Frequency Base Voltage Maximum Voltage Minimum Freq Maximum Freq Stop Select Current Limit Overload Mode Overload Current Sec Curr Limit Adaptive I Lim Minimum Freq Maximum Freq Base Frequency Base Voltage Break Frequency Break Voltage Maximum Voltage DC Boost Select Start Boost Run Boost PWM Frequency Analog Invert 4-20 mA Loss Sel Stop Select DC Hold Time DC HoId Volts DB Enable Motor Type Compensation Freq Select 1 Freq Select 2 Jog Frequency Prst/2nd Accel Upper Presets Accel Time 2 Decel Time 2 Preset Freq 1 Preset Freq 2 Preset Freq 3 Preset Freq 4 Preset Freq 5 Preset Freq 6 Preset Freq 7 Skip Freq 1 Skip Freq 2 Skip Freq 3 Skip Freq Band MOP Increment Analog Filter 66 65 42 70 4 3 2 21 5 7 8 17 18 20 16 19 10 36 37 38 141 149 16 19 17 18 49 50 20 9 48 83 45 84 81 10 12 13 11 41 52 5 6 24 26 72 30 31 27 28 29 73 74 75 76 32 33 34 35 22 144 0.01 Hz 0.01 Hz 0.01 Hz 1 degree C. Numeric 1% 1% Text Text 0.1 Seconds 0.1 Seconds 1 Hz 1 Volt 1 Volt 1 Hz 1 Hz Text 1% Text 0.1 Amps 1% Text 1 Hz 1 Hz 1 Hz 1 Volt 1 Hz 1 Volt 1 Volt Text 1 Volt 1 Volt 0.1 kHz Text Text Text 0.1 Seconds 1 Volt Text Text Text Text Text 0.1 Hz Text Text 0.1 Seconds 0.1 Seconds 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 1 Hz 1 Hz 1Hz 1 Hz 1 Hz/Second Text 0.00 0.00 0.00 0 0 0 0 --0.0 0.0 40 25% of DRV 25% of DRV 0 40 -20% of DRC -20% of DRC 0 -0 40 40 25% of DRV 0 0 25% of DRV -0 0 2.0 ---0.0 0 -----0 --0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0 0 0 0 0.00 -- Maximum Two times drive output current Maximum Voltage Two times rated drive output power 410 - 230V Drive 815 - 460V Drive Maximum Frequency +400.00 400.00 100 Max. Fault Number 200% Drive Rated Power 200% of Rated Drive Output Current --3600.0 3600.0 400 100% of Max. Drive Rated Volts 110% of Max. Drive Rated Volts 120 400 -150% of Drive Rated Current (DRC) -115% of Drive Rated Current (DRC) 150% of Drive Rated Current (DRC) -120 400 400 100% of Max. Drive Rated Volts 120 50% of Maxi. Drive Rated Volts 110% of Max. Drive Rated Volts -25% of Max. Drive Rated Volts 25% of Max. Drive Rated Volts 8.0 ---150.0 25% of Maximum Drive Rated Volts ------400.0 --3600.0 3600.0 400.0 400.0 400.0 400.0 400.0 400.0 400.0 400 400 400 15 255.00 -- Factory Setting -----0.00 -----Three Wire Adapter 1 10.0 10.0 60 100% of Max. DRV 100% of Max. DRV 0 60 Ramp 150% of DRC No Derating 115% of DRC 0 Enabled 0 60 60 100% of Max. DRV 30 Drive Size Depend. 100% of Max. DRV Break Point Drive Size Depend. 0 4.0 Disabled Stop/Fault Ramp 0.0 0 Disabled Induc/Reluc Comp. Adapter 1 Remote Pot 10.0 Preset Disabled 5.0 5.0 10.0 20.0 30.0 40.0 50.0 60.0 0.0 400 400 400 0 1.00 100%