Download 2 - Igor Chudov

Transcript
1305 Parameter List
Parameter Group
Metering
Set Up
Advanced Setup
Frequency Set
18
Parameter Name
Output Current
Output Voltage
Output Power
DC Bus Voltage
No.
54
1
23
53
Units
0.01 Amps
1 Volt
0.01 kW
1 Volt
Minimum
0.00
0
0.00
0
Output Freq
Freq Command
MOP Hertz
Drive Temp
Last Fault
% Output Power
% Output Curr
Input Mode
Freq Select 1
Accel Time 1
Decel Time 1
Base Frequency
Base Voltage
Maximum Voltage
Minimum Freq
Maximum Freq
Stop Select
Current Limit
Overload Mode
Overload Current
Sec Curr Limit
Adaptive I Lim
Minimum Freq
Maximum Freq
Base Frequency
Base Voltage
Break Frequency
Break Voltage
Maximum Voltage
DC Boost Select
Start Boost
Run Boost
PWM Frequency
Analog Invert
4-20 mA Loss Sel
Stop Select
DC Hold Time
DC HoId Volts
DB Enable
Motor Type
Compensation
Freq Select 1
Freq Select 2
Jog Frequency
Prst/2nd Accel
Upper Presets
Accel Time 2
Decel Time 2
Preset Freq 1
Preset Freq 2
Preset Freq 3
Preset Freq 4
Preset Freq 5
Preset Freq 6
Preset Freq 7
Skip Freq 1
Skip Freq 2
Skip Freq 3
Skip Freq Band
MOP Increment
Analog Filter
66
65
42
70
4
3
2
21
5
7
8
17
18
20
16
19
10
36
37
38
141
149
16
19
17
18
49
50
20
9
48
83
45
84
81
10
12
13
11
41
52
5
6
24
26
72
30
31
27
28
29
73
74
75
76
32
33
34
35
22
144
0.01 Hz
0.01 Hz
0.01 Hz
1 degree C.
Numeric
1%
1%
Text
Text
0.1 Seconds
0.1 Seconds
1 Hz
1 Volt
1 Volt
1 Hz
1 Hz
Text
1%
Text
0.1 Amps
1%
Text
1 Hz
1 Hz
1 Hz
1 Volt
1 Hz
1 Volt
1 Volt
Text
1 Volt
1 Volt
0.1 kHz
Text
Text
Text
0.1 Seconds
1 Volt
Text
Text
Text
Text
Text
0.1 Hz
Text
Text
0.1 Seconds
0.1 Seconds
0.1 Hz
0.1 Hz
0.1 Hz
0.1 Hz
0.1 Hz
0.1 Hz
0.1 Hz
1 Hz
1 Hz
1Hz
1 Hz
1 Hz/Second
Text
0.00
0.00
0.00
0
0
0
0
--0.0
0.0
40
25% of DRV
25% of DRV
0
40
-20% of DRC
-20% of DRC
0
-0
40
40
25% of DRV
0
0
25% of DRV
-0
0
2.0
---0.0
0
-----0
--0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0.00
--
Maximum
Two times drive output current
Maximum Voltage
Two times rated drive output power
410 - 230V Drive
815 - 460V Drive
Maximum Frequency
+400.00
400.00
100
Max. Fault Number
200% Drive Rated Power
200% of Rated Drive Output Current
--3600.0
3600.0
400
100% of Max. Drive Rated Volts
110% of Max. Drive Rated Volts
120
400
-150% of Drive Rated Current (DRC)
-115% of Drive Rated Current (DRC)
150% of Drive Rated Current (DRC)
-120
400
400
100% of Max. Drive Rated Volts
120
50% of Maxi. Drive Rated Volts
110% of Max. Drive Rated Volts
-25% of Max. Drive Rated Volts
25% of Max. Drive Rated Volts
8.0
---150.0
25% of Maximum Drive Rated Volts
------400.0
--3600.0
3600.0
400.0
400.0
400.0
400.0
400.0
400.0
400.0
400
400
400
15
255.00
--
Factory Setting
-----0.00
-----Three Wire
Adapter 1
10.0
10.0
60
100% of Max. DRV
100% of Max. DRV
0
60
Ramp
150% of DRC
No Derating
115% of DRC
0
Enabled
0
60
60
100% of Max. DRV
30
Drive Size Depend.
100% of Max. DRV
Break Point
Drive Size Depend.
0
4.0
Disabled
Stop/Fault
Ramp
0.0
0
Disabled
Induc/Reluc
Comp.
Adapter 1
Remote Pot
10.0
Preset
Disabled
5.0
5.0
10.0
20.0
30.0
40.0
50.0
60.0
0.0
400
400
400
0
1.00
100%