NCP1562−100WGEVB
DESIGN SPECIFICATIONS
Active Clamp Forward Topology
The flexibility of the NCP1562 is demonstrated by
examining a detailed design of a dc−dc converter for the
telecom system. The converter delivers up to 100 W at
3.3 V. The converter specifications are listed in Table 1. A
forward active clamp topology is selected for the converter,
as it provides very high efficiency.
The active clamp forward (ACF) topology has multiple
advantages compared to a traditional forward converter. The
benefits of the active clamp topology can be easily
maximized once the unique characteristics of this topology
are fully understood. Figure 2 shows a simplified schematic
of an active clamp forward topology. The transformer model
(TX1) consists of an ideal transformer, magnetizing (LMAG)
and leakage (LLKG) inductances.
The active clamp network consists of the P-channel clamp
switch (Qclamp) and clamp capacitor (Cclamp). This
configuration is known as low side active clamp. A high side
clamp could have been implemented using an N-channel
MOSFET and clamp capacitor in parallel with the
transformer primary. However, it requires a floating gate
drive signal increasing system cost and complexity.
Table 1. DESIGN SPECIFICATIONS
Parameter
Input Voltage
Frequency
Symbol
Min
Max
Vin (V)
33
76
fSW(kHz)
Full Load Efficiency
h (%)
90
−
D
−
65%
Duty Ratio
Output Voltage
350 (typ)
Vout (V)
3.267
3.333
Vout(rip) (mV)
−
50
Output Current
Iout (A)
3
30
Output Power
Pout (W)
−
100
TA (C)
−
Output Voltage Ripple
Ambient Temperature
Derating Factor
−
TX1
+
Vin
−
50
90%
NP:NS = 1:N
ISEC/N
IMAG
Lout
Synchronous
Rectifier
Control
LMAG
LLKG
QFW
Cout
IP
QREC
NCP1562
OUT1
OUT2
ISEC
Qmain
Cdrain
Cclamp
Qclamp
CC
Figure 2. Active Clamp Forward Converter
The differences between traditional and active clamp
forward converters are during the main switch off time. In
the active clamp topology, the transformer is reset at a lower
voltage during the complete off time instead of a higher
voltage during a shorter period of time. Figure 3 shows a
comparison between the drain waveforms of both
topologies. The traditional forward waveform was taken
with a primary:reset winding ratio of 5:3 instead of 1:1. The
5:3 ratio allowed operation above 50% duty cycle.
Reset Winding
Active
Clamp
Figure 3. Drain Voltage Waveforms for Traditional
and Active Clamp Forward Topologies