Download 2012 - Bestway
Transcript
7.16 Config Boom Interaction Direction
The B.I. DIRECTION option of the CONFIG menu defines the direction of interaction between
the left and right booms.
B.I. Direction=
SAME
OPPOSITE
Choose the desired value and press ENT to save the new value. The default value is SAME.
This parameter works together with the Boom Interaction parameter. Refer to the above
description of the Boom Interaction parameter for details.
7.17 Config Valid Window
NOTE: This option is not intended for sprayer boom height control!
The VALID WINDOW option of the CONFIG menu limits the range of sonar sensor height
readings that is accepted. Any height reading outside the valid range will be rejected.
Valid Window=
Disabled
Choose "Disabled" or a value in the range of 0.5" to 40.00", in steps of 0.5", and press ENT to
save the new Valid Window. The default value is "Disabled".
When set to "Disabled", the Valid Window has no effect. When set to some other value, the valid
range of heights is calculated based on the current Target Height plus or minus the Valid Window.
For example, if the Target Height is 35.0" and the Valid Window is set to 4.0", only height readings
between 31.0" and 39.0" will be accepted. Readings outside this range will be treated as
out-of-range.
This feature is intended for height control applications with a limited range of operation. For
example, when controlling header depth on a potato harvester, the Valid Window can be used to
exclude too-short readings due to tall weeds.
7.18 Config No-Range Lower
NOTE: This option is not available for sprayer boom height control.
The NO-RANGE LOWER option of the CONFIG menu controls the behavior of the system when
a sonar sensor does not report a distance reading ("No Range"). This usually happens when the
boom swings too high above the ground. When the distance to the ground is beyond the sonar
sensor's range, or if the received echo is too weak, the sonar sensor will not be able to provide a
distance reading. This shows up on the Controller display as "--.-".
This option provides the following display:
No-Range Lower=
Disabled
Choose "Disabled", or a value in the range of 0.5" to 10.00", in steps of 0.5", and press ENT to
save the new value. The default value is "Disabled".
Information subject to change without notice.
Bestway, Inc. – Hiawatha, KS.
22