Download Stage 2
Transcript
ADJUSTING THE TEMPERATURE SET POINT Be sure the temperature curve is deactivated (see above). Set the parameter selection knob to SET POINT/ TEMP.CURVE. The current temperature set point appears flashing on the display. Using the adjustment knob, adjust the set point to the desired value. PROGRAMMING THE TEMPERATURE CURVE NOTES: All six points of the curve must be specified. If you do not need six different points, repeat your last temperature set point for each unnecessary point of the curve. To reduce the risk of errors: - The highest possible day number is 99. You can not specify decreasing day numbers. You can not specify an increasing temperature curve. The temperature variation can not exceed 3°F (1.6°C) per day. To specify the six points of the temperature curve: Be sure the temperature curve is deactivated (see above). Set the parameter selection knob to SET POINT/TEMP.CURVE. The current temperature set point appears flashing on the display. Press the push-button. The word OFF appears on the display, indicating that the temperature curve is deactivated. CWS-T-11HA.rev.03 21