Download Nanodac Recording Temperature Controller User Manual
Transcript
nanodac RECORDER/CONTROLLER: USER GUIDE 5.3 PARAMETER LIST (Cont.) Parameter path Description Type Hex Dec Resolution VirtualChannel.12.Alarm2.Deviation VirtualChannel.12.Alarm2.Dwell VirtualChannel.12.Alarm2.Hysteresis VirtualChannel.12.Alarm2.Inactive VirtualChannel.12.Alarm2.Latch VirtualChannel.12.Alarm2.NotAcknowledged VirtualChannel.12.Alarm2.Reference VirtualChannel.12.Alarm2.Status VirtualChannel.12.Alarm2.Threshold VirtualChannel.12.Alarm2.Type VirtualChannel.12.Main.Descriptor VirtualChannel.12.Main.Disable VirtualChannel.12.Main.HighCutOff VirtualChannel.12.Main.Input1 VirtualChannel.12.Main.Input2 VirtualChannel.12.Main.LowCutOff VirtualChannel.12.Main.ModbusInput VirtualChannel.12.Main.Operation VirtualChannel.12.Main.Period VirtualChannel.12.Main.Preset VirtualChannel.12.Main.PresetValue VirtualChannel.12.Main.PV VirtualChannel.12.Main.Reset VirtualChannel.12.Main.Resolution VirtualChannel.12.Main.Rollover VirtualChannel.12.Main.Status VirtualChannel.12.Main.TimeRemaining VirtualChannel.12.Main.Trigger VirtualChannel.12.Main.Type VirtualChannel.12.Main.Units VirtualChannel.12.Main.UnitsScaler VirtualChannel.12.Trend.Colour VirtualChannel.12.Trend.SpanHigh VirtualChannel.12.Trend.SpanLow Deviation alarm ‘Deviation Value’ Alarm dwell time Alarm hysteresis value 1 = alarm source safe and ack’d (if necessary) As VirtualChannel1.Alarm1.Latch 1 = alarm has not been acknowledged Deviation alarm ‘Reference’ value As VirtualChannel1.Alarm1.Status Alarm trigger threshold As VirtualChannel1.Alarm1.Type Virtual Channel descriptorl 1 = Virtual channel disabled The highest input value that will be totalised/counted Input 1 value Input 2 value The lowest input value that will be totalised/counted Modbus input value As VirtualChannel1.Main.Operation The time period over which the calculation is made Initiate preset. 0 = No; 1 = Yes The Preset value The virtual channel output value Initiate reset. 0 = No; 1 = Yes Number of decimal places (0 to 6) A pulse signal to indicate PV (output) has just rolled over As VirtualChannel1.Main.Status Time remaining before the calculation is made Increment/decrement counter. 0 = No; 1 = Yes As VirtualChannel1.Main.Type Units descriptor Units scaler for totalisers As VirtualChannel1.Trend.Colour Specifies the highest PV (output value) to be displayed Specifies the lowest PV (output value) to be displayed float32 time_t float32 bool uint8 bool float32 uint8 float32 uint8 string_t bool float32 float32 float32 float32 float32 uint8 int32 bool float32 float32 bool uint8 bool uint8 time_t bool uint8 string_t float32 uint8 float32 float32 21e7 21e5 21e4 21ee 21e1 21ef 21e6 014f 21e3 21e0 4c29 21a3 2185 2187 2188 2184 2186 2181 218a 218c 218d 014c 218b 2182 2191 014d 2189 218e 2180 4c3e 2183 21a0 21a2 21a1 8679 8677 8676 8686 8673 8687 8678 335 8675 8672 19497 8611 8581 8583 8584 8580 8582 8577 8586 8588 8589 332 8587 8578 8593 333 8585 8590 8576 19518 8579 8608 8610 8609 Same as VirtualChannel.12.Main.PV Set by Network.Modbus.TimeFormat Same as VirtualChannel.12.Main.PV Not applicable Not applicable Not applicable Same as VirtualChannel.12.Main.PV Not applicable Same as VirtualChannel.12.Main.PV Not applicable Not applicable Not applicable Set by VirtualChannel.12.Main.Resolution Set by VirtualChannel.12.Main.Resolution Set by VirtualChannel.12.Main.Resolution Set by VirtualChannel.12.Main.Resolution Set by VirtualChannel.12.Main.Resolution Not applicable Not applicable Not applicable Set by VirtualChannel.12.Main.Resolution Set by VirtualChannel.12.Main.Resolution Not applicable Not applicable Not applicable Not applicable Set by Network.Modbus.TimeFormat Not applicable Not applicable Not applicable 1dp Not applicable Same as VirtualChannel.12.Main.PV Same as VirtualChannel.12.Main.PV VirtualChannel.13.Alarm1.Acknowledge VirtualChannel.13.Alarm1.Acknowledgement VirtualChannel.13.Alarm1.Active VirtualChannel.13.Alarm1.Amount VirtualChannel.13.Alarm1.AverageTime VirtualChannel.13.Alarm1.Block VirtualChannel.13.Alarm1.ChangeTime VirtualChannel.13.Alarm1.Deviation VirtualChannel.13.Alarm1.Dwell VirtualChannel.13.Alarm1.Hysteresis VirtualChannel.13.Alarm1.Inactive VirtualChannel.13.Alarm1.Latch VirtualChannel.13.Alarm1.NotAcknowledged VirtualChannel.13.Alarm1.Reference VirtualChannel.13.Alarm1.Status VirtualChannel.13.Alarm1.Threshold VirtualChannel.13.Alarm1.Type VirtualChannel.13.Alarm2.Acknowledge VirtualChannel.13.Alarm2.Acknowledgement VirtualChannel.13.Alarm2.Active VirtualChannel.13.Alarm2.Amount VirtualChannel.13.Alarm2.AverageTime VirtualChannel.13.Alarm2.Block VirtualChannel.13.Alarm2.ChangeTime VirtualChannel.13.Alarm2.Deviation VirtualChannel.13.Alarm2.Dwell VirtualChannel.13.Alarm2.Hysteresis VirtualChannel.13.Alarm2.Inactive VirtualChannel.13.Alarm2.Latch VirtualChannel.13.Alarm2.NotAcknowledged VirtualChannel.13.Alarm2.Reference VirtualChannel.13.Alarm2.Status VirtualChannel.13.Alarm2.Threshold VirtualChannel.13.Alarm2.Type VirtualChannel.13.Main.Descriptor VirtualChannel.13.Main.Disable VirtualChannel.13.Main.HighCutOff VirtualChannel.13.Main.Input1 VirtualChannel.13.Main.Input2 VirtualChannel.13.Main.LowCutOff VirtualChannel.13.Main.ModbusInput VirtualChannel.13.Main.Operation VirtualChannel.13.Main.Period VirtualChannel.13.Main.Preset VirtualChannel.13.Main.PresetValue VirtualChannel.13.Main.PV 1 = acknowledge alarm 1 = alarm acknowledged 1 = alarm source active, or safe but not ack’d Rate-of-change alarm ‘Amount’ Rate-of-change alarm ‘Average time’ 0 = Blocking alarms off; 1 = Blocking alarms on Rate-of-change alarm ‘Change Time’ Deviation alarm ‘Deviation Value’ Alarm dwell time Alarm hysteresis value 1 = alarm source safe and ack’d (if necessary) As VirtualChannel1.Alarm1.Latch 1 = alarm has not been acknowledged Deviation alarm ‘Reference’ value As VirtualChannel1.Alarm1.Status Alarm trigger threshold As VirtualChannel1.Alarm1.Type 1 = acknowledge alarm 1 = alarm acknowledged 1 = alarm source active, or safe but not ack’d Rate-of-change alarm ‘Amount’ Rate-of-change alarm ‘Average time’ 0 = Blocking alarms off; 1 = Blocking alarms on Rate-of-change alarm ‘Change Time’ Deviation alarm ‘Deviation Value’ Alarm dwell time Alarm hysteresis value 1 = alarm source safe and ack’d (if necessary) As VirtualChannel1.Alarm1.Latch 1 = alarm has not been acknowledged Deviation alarm ‘Reference’ value As VirtualChannel1.Alarm1.Status Alarm trigger threshold As VirtualChannel1.Alarm1.Type Virtual Channel descriptor 1 = Virtual channel disabled The highest input value that will be totalised/counted Input 1 value Input 2 value The lowest input value that will be totalised/counted Modbus input value As VirtualChannel1.Main.Operation The time period over which the calculation is made Initiate preset. 0 = No; 1 = Yes The Preset value The virtual channel output value bool bool bool float32 time_t uint8 uint8 float32 time_t float32 bool uint8 bool float32 uint8 float32 uint8 bool bool bool float32 time_t uint8 uint8 float32 time_t float32 bool uint8 bool float32 uint8 float32 uint8 string_t bool float32 float32 float32 float32 float32 uint8 int32 bool float32 float32 01d8 2250 224b 2248 224a 2242 2249 2247 2245 2244 224e 2241 224f 2246 0152 2243 2240 01d9 2270 226b 2268 226a 2262 2269 2267 2265 2264 226e 2261 226f 2266 0153 2263 2260 4c44 2223 2205 2207 2208 2204 2206 2201 220a 220c 220d 0150 472 8784 8779 8776 8778 8770 8777 8775 8773 8772 8782 8769 8783 8774 338 8771 8768 473 8816 8811 8808 8810 8802 8809 8807 8805 8804 8814 8801 8815 8806 339 8803 8800 19524 8739 8709 8711 8712 8708 8710 8705 8714 8716 8717 336 Not applicable Not applicable Not applicable Same as VirtualChannel.13.Main.PV Set by Network.Modbus.TimeFormat Not applicable Not applicable Same as VirtualChannel.13.Main.PV Set by Network.Modbus.TimeFormat Same as VirtualChannel.13.Main.PV Not applicable Not applicable Not applicable Same as VirtualChannel.13.Main.PV Not applicable Same as VirtualChannel.13.Main.PV Not applicable Not applicable Not applicable Not applicable Same as VirtualChannel.13.Main.PV Set by Network.Modbus.TimeFormat Not applicable Not applicable Same as VirtualChannel.13.Main.PV Set by Network.Modbus.TimeFormat Same as VirtualChannel.13.Main.PV Not applicable Not applicable Not applicable Same as VirtualChannel.13.Main.PV Not applicable Same as VirtualChannel.13.Main.PV Not applicable Not applicable Not applicable Set by VirtualChannel.13.Main.Resolution Set by VirtualChannel.13.Main.Resolution Set by VirtualChannel.13.Main.Resolution Set by VirtualChannel.13.Main.Resolution Set by VirtualChannel.13.Main.Resolution Not applicable Not applicable Not applicable Set by VirtualChannel.13.Main.Resolution Set by VirtualChannel.13.Main.Resolution Page 104 HA030554 Issue 1 Jul 10