Download User Manual SONO-VARIO

Transcript
18/48
4-20mA Current output: Measurement conversion for 0 to 20% moisture at different sand
grading ranges with standard calibration curve Cal1:
Grading range
and bulk
density
3
in kg/dm
Moisture
value at 4mA
current at the
analog output
(theoretically)
A value of 0% moisture
content thus conforms to
an output current in mA
at the analog output of:
Moisture value at 20mA
output current at the
analog output:
0-2mm
1.5
0.00%
4mA
20%
0-2mm
1.6
-0.29%
4.24mA
18.4%
0-4mm
1.7
-0.55%
4.48mA
17.1%
0-5mm
1.8
-0.78%
4.72mA
15.9%
0-8mm
1.9
-0.98%
4.96mA
14.8%
2.0
-1.16%
5.2mA
13.8%
2.1
-1.33%
5.44mA
12.9%
0-20mA Current output: Measurement conversion for 0 to 20% moisture at different sand
grading ranges with standard calibration curve Cal1:
Grading range
and bulk
density
3
in kg/dm
Moisture
value at 4mA
current at the
analog output
(theoretically)
A value of 0% moisture
content thus conforms to
an output current in mA
at the analog output of:
Moisture value at 20mA
output current at the
analog output:
0-2mm
1.5
0.00%
0mA
20%
0-2mm
1.6
-0.29%
0.3mA
18.4%
0-4mm
1.7
-0.55%
0.6mA
17.1%
0-5mm
1.8
-0.78%
0.9mA
15.9%
0-8mm
1.9
-0.98%
1.2mA
14.8%
2.0
-1.16%
1.5mA
13.8%
2.1
-1.33%
1.8mA
12.9%
Please note: The guide values only apply for sand. For measuring gravel and grit with different
gradings, it is recommended to use the standard calibration curve Cal1 or Cal6. Here, the analog
output 0(4)-20mA corresponds to 0-20% moisture.