Download M32150 datasheet
Transcript
SERIAL I/O 12.2 Registers related to serial I/O 12.2.6 SIOn status register (n = 0, 1) SIO0 status register (S0STAT) SIO1 status register (S1STAT) D0 <Address : H'0080 0108> <Address : H'0080 0118> 1 2 3 4 5 6 RXERR FE PE OE RXCP TXCP D7 TBEMP < at reset : H'03> D Bit name 0 Not assigned. 1 RXERR 0: No receive error (Receive error sum) 1: Receive error FE (Framing error) 0: No receive framing error ※Used only in UART mode 1: Receive framing error PE (Parity error) 0: No receive parity error ※Used only in UART mode 1: Receive parity error OE 0: No receive overrun error (Overrun error) 1: Receive overrun error RXCP 0: Receive uncompleted (Receive complete : 1: Receive completed 2 3 4 5 Function Receive buffer full) 6 Ini. R W 0 0 - 0 ○ - 0 ○ - 0 ○ - 0 ○ - 0 ○ - 1 ○ - 1 ○ - (Receive buffer full) TXCP 0: Transmit uncompleted (Transmit complete : (Data exist in transmit shift Transmit shift register empty) register) 1: Transmit completed (Transmit shift register empty) 7 TEMP 0: Data exist in transmit buffer (Transmit buffer empty) 1: Transmit buffer empty W = -: Write invalid 12-14 M32150F4TFP User's Manual