Download Twido programmable controllers
Transcript
Communications Transmission/ reception tables When in Transmit Only mode, the Control and Transmission tables are filled in prior to executing the EXCHx instruction, and can be of type %KW or %MW. No space is required for the reception of characters in Transmission only mode. Once all bytes are transmitted, %MSGx.D is set to 1, and a new EXCHx instruction can be executed. When in Transmit/Receive mode, the Control and Transmission tables are filled in prior to executing the EXCHx instruction, and must be of type %MW. Space for up to 256 reception bytes is required at the end of the Transmission table. Once all bytes are transmitted, the Twido controller switches to reception mode and waits to receive any bytes. When in Reception only mode, the Control table is filled in prior to executing the EXCHx instruction, and must be of type %MW. Space for up to 256 reception bytes is required at the end of the Control table. Twido controller immediately enters the reception mode and waits to receive any bytes. Reception ends when end of frame bytes used have been received, or the Reception table is full. In this case, an error (receive table overflowed) appears in the word %SW63 and %SW64. If a non-zero timeout is configured, reception ends when the timeout is completed. If a zero timeout value is selected, there is no reception timeout. Therefore to stop reception, %MSGx.R input must be activated. Message Exchange The language offers two services for the communication: z EXCHx instruction: to transmit/receive messages z %MSGx Function Block: to control the message exchanges. Twido controller uses the protocol configured for that port when processing an EXCHx instruction. Note: Each communications port can be configured for different protocols or the same. The EXCHx instruction or %MSGx function block for each communications port is accessed by appending the port number (1 or 2). EXCHx Instruction The EXCHx instruction allows the Twido controller to send and/or receive information to/ from ASCII devices. The user defines a table of words (%MWi:L or %KWi:L) containing control information and the data to be sent and/or received (up to 256 bytes in transmission and/or reception). The format for the word table is described earlier. A message exchange is performed using the EXCHx instruction: Syntax: [EXCHx %MWi:L] where: x = port number (1 or 2) L = number of words in the control words and transmission and reception tables The Twido controller must finish the exchange from the first EXCHx instruction before a second can be launched. The %MSGx function block must be used when sending several messages. The processing of the EXCHx list instruction occurs immediately, with any transmissions started under interrupt control (reception of data is also under interrupt control), which is considered background processing. 120 TWD USE 10AE
Related documents
Twido Soft - Elmatik AS
Automates programmables Twido - Site de l`académie de Grenoble
Automates programmables Twido
Twido Automates programmables - Maintenance
Automates programmables Twido
TwidoSuite V1.2
3 - Schneider Electric
Descargar (PDF, 4.73 Mb, abre una nueva - schneider
Twido installazione
Automates programmables Twido
Controlador programable Twido
Cisco Systems 10200 User's Manual