Download GWSDAT FAQs

Transcript
Because the minimum well spacing required for effective concentration contouring varies from
site to site, the user’s judgement is required in deciding whether the available data merits
contouring. The presence of “redundant” data points that can be removed without significantly
changing the concentration distribution is an indication that the monitoring well spacing is
more than sufficient.
In the event that only a small number of wells (i.e. <4) are present, then GWSDAT v2.0
includes a circle plot option, which represents the data as circles coloured and sized to solute
concentration, thereby avoiding the need to use potentially misleading concentration
contours.
Similar arguments apply to the contouring of groundwater elevation data, although in the
absence of significant topographic variation/ geological heterogeneity or groundwater
abstraction/ water injection groundwater piezometric surfaces should be locally planar. The
adaptive kriging algorithm used by GWSDAT to derive the piezometric surface requires a
minimum of 4 well locations; flow direction arrows can, however, be generated for only 3 well
locations.
Q: How does the non- detect substitution function work?
A:
GWSDAT handles non-detect data by a method of substitution. In accordance with general
convention, the default option is to substitute the non-detect data with half its detection limit,
e.g. ND<50ug/l is substituted with 25ug/l. Alternatively, non-detect data can be substituted
with its full detection limit, e.g. ND<50ug/l is substituted with 50ug/l. Note that the entry of
zero concentration values is not permitted.
Q: How does the software handle Non Aqueous Phase Liquid (NAPL) data?
A:
During data analysis the user has the option to ignore the presence of NAPL when fitting the
spatiotemporal model, or substitute detections of NAPL with site maximum solute
concentrations. NAPL substitution should only be used if it is known that the solutes entered
into GWSDAT are derived from dissolution of the NAPL. This functionality was introduced to
avoid the situation whereby an area of wells containing NAPL appears as a minimum on
concentration contour plots because groundwater solute concentration data is not available.
Note: Any solutes that are not derived from the NAPL can be excluded from the NAPL
substitution process by flagging them as “NotInNAPL” or “E-acc” in the historical monitoring
data table of the input worksheet. Note also that only one solute data point needs to be
flagged to remove that solute from the substitution algorithm.