Download SIMSIDES User Guide
Transcript
SIMSIDES User Guide 17 • Solver options: Type: Variable Step ; Max Step Size: Auto Note that integrator building blocks are identified in order to properly compute the equivalent load capacitances required for the incomplete settling error model. Computing Output Spectrum The output spectrum of the Σ∆M can be computed in SIMSIDES by following the next steps: • Set up model parameters by using the M-file shown in Figure 1.16. • Simulate the modulator in Figure 1.15b from the menu Simulation -> Start. • Once the simulation has finished, go to Analysis -> Node Spectrum Analysis menu in SIMSIDES. • Define the parameters requested in that menu. In this example, the sampling frequency is defined as fs and a Kaiser window function is used with a number of points N and Beta = 20. • Click on Compute and then Plot, and the output spectrum shown in Figure 1.17 is displayed. Modulator Output (Magnitude) Spectrum 0 −20 Magnitude (dB) −40 −60 −80 −100 −120 −140 −160 1 10 2 10 3 10 4 10 Frequency (Hz) 5 10 6 10 Figure 1.17 Output spectrum (magnitude) of the Σ∆M in Figure 1.15b.