Figure 16 – DSM250 Advanced Information Screen Most of the items within the Advanced Information… menu are obvious and not described here, although a less obvious menu item (Bus Status…) is described below. 5.2.4.2.1 Bus Status The DSM250 is capable of monitoring the NMEA 2000® network and displaying certain statistics. Baud Rate: the speed capability of the connected network given in bits per second (bps), Voltage: the network voltage as measured by the DSM250 in Volts, Traffic: the percent usage of the total available bandwidth measured by the DSM250, Receive Rate: the DSM250 measured received rate in frames per second (fps), Transmit Rate: the DSM250 measured transmit rate in frames per second (fps), Error Count: the DSM250 measured error frames since entering the Bus Status screen, Receive Counter: the number of DSM250 measured received frames, and Transmit Counter: the number of DSM250 measured transmitted frames. Figure 17 – Bus Status Display Revision 1.6.2 Page 33