Programming Model
ERBFI: Enable Received Data Available Interrupt. This bit, when
set, enables the Received Data Available Interrupt.
When DLAB = 1:
3
IEDHx: IEDHx is the Divisor Latch High (most significant byte)
Register that contains the upper 8 bits of the baud rate divisor for the
UART. This register in conjunction with the Divisor Latch Low
Register form a 16-bit baud rate divisor.
The Interrupt Identification/FIFO Control Register (IDFCx) consists of
two separate registers whose accessibility is based on the mode of
operation (either read or write).
IDFCx: IDFCx is the read-only Interrupt Identification Register that
identifies the source of an interrupt. The fields within this register are
defined as follows:
FENS1-0: FIFOs Enabled Status. These bits are the FIFO status bits
that are shown in the table below.
Table 3-38. FENS1-0 Status
FIFOEN
FENS1-0
Status
0
00
FIFOs Disabled
1
11
FIFOs Enabled
IID2-0,IPEN: Interrupt ID, Interrupt Pending. These bits identify
the interrupt control functions that are shown in the table below.
Table 3-39. UART Interrupt Control Functions
IID2
IID1
IID0
IPEN
Priority
Level
0
0
0
1
---
0
1
1
0
Highest
3-138
Interrupt
Type
Interrupt Source
Interrupt Reset
Control
No Interrupt
Pending
---
---
Receiver Line
Status
Overrun Error or Parity
Error or Framing Error
or Break Interrupt
Reading the Line
Status Register