Installation & User Manual
V2.02
Operation Instructions
2
Operation Instructions
Technical Specs
Power Supply
Current consumption
Current consumption with load (max)
Relay Contact Rating
Operating Temperature
Moisture Resistance
Dimensions - Flush Mount
- Surface Mount
Number of Users
12 - 24V AC or DC
100mA
130mA
5 Amps /240V ac
- 20 C to +60 C
IP 67
W. 87mm D. 21mm H. 119mm
W. 87mm D. 35mm H. 119mm
1000
3
Adding and Removing PIN’s
Code Description
01 Add a Standard User/Toggle User/Manager User PIN
03 Remove any User PIN
Example: To Add User PIN ‘5656'
X key then
Engineer
Code
+
Code = 01
+
PIN = 5656
+
+
PIN = 4545
+
Example: To Remove User PIN ‘4545’
Factory Default PIN codes
X key then
Engineer
Code
The following PIN codes are the Factory Default Settings:
+
Code = 03
- The Default Engineer code is ‘6666’
Example: To Add Toggle User PIN ‘1234’
- User PIN ‘1111’
Note: The User PIN ’1111’ is deactivated when the first User PIN is added to
the keypad.
X key then
Engineer
Code
+
Code = 01
+
1 = Toggle User
PIN = 1234
+
1
Example: To Add Manager User PIN ‘5678’
2 = Manager User
Restoring Factory Settings
Code
55
X key then
Engineer
Code
Description
Restore Factory Default Settings
Example:
X key then
Engineer
Code
+
Code = 55
+
Note: If Engineer code is lost, Remove the Security Caps (see page 11) and
hold down the X key during power-up and enter the default Engineer
code ‘6666’ immediately. This will restore the factory settings.
+
Code = 01
+
PIN = 5678
+
2
4
Operation Instructions
Operation Instructions
Adding User Cards or Fobs using Keypad
Adding a Batch of Cards or Fobs
Code Description
04 Add Batch of Standard Cards/Toggle Cards/Manager Cards
+
Code = 04
+
Code Description
06 Add Batch of Cards using Keypad
Example: To Add a Single Standard Card... (Card number = 00001234)
Example: To Add a Single Standard Card...
X key then
Engineer
Code
5
Present
new card
+
Present
new card again
X key then
Engineer
Code
+
1234 =
Card number
+
Code = 06
+
To Confirm Card #
+
+
1234 =
Card number
+
To Confirm Standard Card
To Confirm Card #
+
Code = 04
+
To Confirm Standard Card
Example: To Add a Batch of Standard Cards... (Batch = 0000200 to 0001000)
Example: To Add a Batch of Standard Cards...
X key then
Engineer
Code
+
Present First
Card in batch
+
Present Last
Card in Batch
X key then
Engineer
Code
+
Code = 06
+
200 =
Card number
+
To Confirm Card #
+
1000 =
Card number
+
+
To Confirm Standard Cards
To Confirm Card #
+
Code = 04
+
To Confirm Standard Cards
Example: To Add a Batch of Toggle Cards... (Batch = 0003200 to 0004000)
Example: To Add a Batch of Toggle Cards...
X key then
Engineer
Code
+
Present First
Card in batch
+
Present Last
Card in batch
X key then
Engineer
Code
+
Code = 06
+
3200 =
Card number
+
To Confirm Card #
+
1
+
4000 =
Card number
+
To Confirm Toggle Cards
To Confirm Card #
+
Code = 04
+
Present First
Card in batch
To Confirm Toggle Card
Example: To Add a Batch of Manager User Cards... (Batch = 001200 to 001250)
Example: To Add a Batch of Manager User Cards...
X key then
Engineer
Code
1
+
+
Present Last
Card in batch
X key then
Engineer
Code
+
Code = 06
+
1200 =
Card number
+
To Confirm Card #
+
2
To Confirm Manager User Cards
+
1250 =
Card number
+
+
To Confirm Card #
2
To Confirm Manager User Card
6
Operation Instructions
Operation Instructions
Adding a Card and PIN
Removing a Batch of Cards or Fobs
Code Description
07 Add a Card and a User PIN
Code Description
05 Removing a Batch of Cards
Example: To Add a Card & PIN... (Card number = 00001234, PIN = 4444)
X key then
Engineer
Code
+
Code = 07
7
+
Present Card
00001234
+
PIN = 4444
Example: To remove a Single Card...
X key then
Engineer
Code
+
Code = 05
+
Present card
to remove
+
Present
Card again
+
Present Last
Card in Batch
+
+
To Confirm Card removal
To Confirm Standard Card & PIN
Example: To Remove a Batch of Cards...
Example: To Add a Toggle Card & PIN... (Card number = 00001234, PIN = 4444)
X key then
Engineer
Code
+
Code = 07
+
Present Card
00001234
+
X key then
Engineer
Code
+
Code = 05
+
Present First
Card in batch
PIN = 4444
+
To Confirm Card removal
+
1
Removing a Card and PIN
To Confirm Toggle Card & PIN
Example: To Add a Mgr User Card & PIN... (Card number = 00001234, PIN = 4444)
X key then
Engineer
Code
+
Code = 07
+
Present Card
00001234
+
PIN = 4444
Code Description
08 Removing a Card (and any associated PIN)
09 Removing a Card (and any associated PIN) using Keypad
Example: To Remove a Card...
X key then
Engineer
Code
+
+
Code = 08
+
Present card
to remove
2
To Confirm Mgr User Card & PIN
+
To Confirm Card/PIN removal
Example: To Remove a Card using Keypad... (Card number = 00001234)
X key then
Engineer
Code
+
Code = 09
+
1234 =
Card number
+
To Confirm Card/PIN removal
8
Operation Instructions
Operation Instructions
9
Table 1
Changing Relay Times and Engineer Codes
Code
10
11
12
13
14
Description
Change the Number of PIN Digits
Change the Engineer Code
Change the Relay Active Time
Change the Door Ajar Time
Change the Guest Buzzer Time
Default Settings
4 digit PIN (4,5,6 only)
6666
5 seconds (0-255)
30 seconds (2-255)
3 seconds (1-10)
Note: The Number of PIN digits can not be reduced once a User Pin has
been added.
Example: To Change the Engineer Code..
X key then
Engineer
Code
+
Code = 11
+
Code = 12
+
+
Time = 14
+
Example: To Change the Relay Active Time to a 200msec pulse..
X key then
Engineer
Code
+
Code = 12
+
Input 1
0
Default
Wiring
Diagrams
Input 2
Output 1
Door 1 Exit
Button
Door 1
Contact
Alarm/
Buzzer
Page 12
1
Door 1 Exit
Button
Door 1
Contact
Follow
Relay 1
Page 12
2
Door 1 Exit
Button
Fire Alarm
Override
Alarm/
Buzzer
Page 13
3
Door 1
Contact
Interlock
I/P
Interlock
O/P
Page 14
4
Door 1 Exit
Button
Alarm Panel
I/P
Alarm Panel
O/P
Page 15
Turning Features ON or OFF
New
Engineer
Code
Example: To Change the Relay Active Time to 14 seconds..
X key then
Engineer
Code
Option
Time = 0
+
Changing Input/Output Options
Code
20
21
22
23
24
25
26
27
28
31
32
33
Description
Set Silent Operation on/off
Set Ajar Alarm on/off
Set Guest Button on/off
Set Duress codes on/off
Set Toggle Relay on/off
Set Door Forced Alarm on/off
Set Anti-Tail Gate on/off
Set Constant Backlight on/off
Set Invalid PIN Lockout on/off
Set Card Or PIN on/off
Set Card And PIN on/off
Set Card And Any PIN on/off
Note: 0 = Off
Default Settings
Off
On
On
Off
On
On
Off
On
On (3 Retries)
On
Off
Off
1= On
Example: To Set the Backlight to always stay ON...
Code Description
30 Change the Input and Output Options
X key then
Engineer
Code
Example:
+
Code = 27
+
ON = 1
Example: To Set the Backlight to stay ON for 10 seconds only after a key press...
X key then
Engineer
Code
+
Code = 30
+
Enter 0-4
Refer to
Table 1
X key then
Engineer
Code
+
Code = 27
+
OFF = 0
10 Installation Diagrams
Installation Diagrams
11
Flush Mounting
Fix Surface Mount Collar to
wall, ensure arrow is
pointing upwards
Keypad is mounted to pattress box using security
screws provided. Both Security Caps are
then clipped onto Keypad.
Surface Mounting
Fix Surface Mount Collar to wall (as above).
After wiring is complete, Keypad may
then be screwed to Surface Mount Collar
using security screws provided.
Both Security Caps are then
clipped onto keypad
To attach Security Caps hook tabs
into holes and push on.
To release Security Caps push a
screwdriver into slots on the side
and pull forward.
To attach Security Caps hook tabs
into holes and push on.
12
Wiring Diagrams
Wiring Diagrams
13
Wiring Diagrams for Door 1
and Fire Alarm Override
Wiring Diagrams for Door 1
Door 1 Exit Button
12V Linear
Power supply
Door 1 Exit Button
12V Linear
Power supply
0V
0V
Fire Alarm
Panel
12V
12V
12V
IP1
IP2
0V
OP1
NO
COM TAMP
TAMP
NC
0V
12V
12V
IP1
IP2
0V
OP1
NO
COM TAMP
TAMP
NC
Door 1
Contact
0V
When the fire alarm
is activated (0V removed
from IP2) the door will
be opened
12V
Door MagLock
Door MagLock
Sounder
or
Follow
Volt Free
Tamper Contacts
1 and 2
12 - 24 VAC
Volt Free
Tamper Contacts
1 and 2
12 - 24 VAC
12V
0V
NO
COM
NC
12V
0V
NO
COM
NC
12 - 24 VAC
Wiring for StikeLock only using 12 - 24VAC supply
Sounder
Common OV from the Fire Alarm Panel
and the OV from the Keypad to avoid
any ground loop issues.
12 - 24 VAC
0V
Note: All OV shown in the diagram are connected
to OV at the back of the keypad terminal block.
Wiring for StikeLock only using 12 - 24VAC supply
0V
Note: All OV shown in the diagram are connected
to OV at the back of the keypad terminal block.
14
Wiring Diagrams
Wiring Diagrams
15
Wiring Diagrams for Door 1
and Alarm Panel connections
Wiring Diagrams for Door 1
and Interlock connections
12V Linear
Power supply
Door 1 Exit Button
12V Linear
Power supply
Door 1
Contact
0V
0V
Alarm Panel
12V
12V
12V
IP1
IP2
0V
OP1
NO
COM TAMP
TAMP
NC
Arm Output (N/O)
12V
IP1
IP2
0V
OP1
NO
COM TAMP
TAMP
NC
Interlock IP from
Interlock OP on 2nd Door
Arm Alarm Input
Interlock OP to
Interlock IP on 2nd Door
Door MagLock
Door MagLock
Volt Free
Tamper Contacts
1 and 2
Volt Free
Tamper Contacts
1 and 2
Only the Manager User can
activate/deactivate the Alarm
Panel. When the Alarm Panel is
activated all other users are
locked out.See notes on Page 16
for explanation of feature.
12 - 24 VAC
12 - 24 VAC
12V
0V
NO
COM
NC
12V
0V
NO
COM
NC
12 - 24 VAC
12 - 24 VAC
Wiring for StikeLock only using 12 - 24VAC supply
Common OV from the Intruder Alarm Panel
and the OV from the Keypad to avoid
any ground loop issues.
0V
Note: All OV shown in the diagram are connected
to OV at the back of the keypad terminal block.
Wiring for StikeLock only using 12 - 24VAC supply
0V
Note: All OV shown in the diagram are connected
to OV at the back of the keypad terminal block.
Quick reference
16 Operation Instructions
Notes:
Invalid PIN Lockout – Entering an invalid PIN 3 times will lockout the keypad for
15 seconds. All lights will flash during this time. Turning this feature off reduces the
security of the keypad.
Quick Reference - Menu Codes
Code
Description
Default Settings
01
Add a User PIN to Door 1
03
Remove a User PIN
04
Add Batch Standard/Toggle/Mgr.User card
05
Remove batch of cards
06
Add Batch of Cards using Keypad
07
Add a Card and a User PIN
08
Remove Card and associated PIN
09
Remove Card and associated PIN with Keypad
10
Change the Number of PIN Digits
11
Change the Engineer Code
12
Change the Relay Active Time
5 seconds (0-255)
13
Change the Door Ajar Time
30 seconds (2-255)
14
Change the Guest Buzzer Time
3 seconds (1-10)
20
Set Silent Operation on/off
Off
21
Set Ajar Alarm on/off
On
Duress codes - If this option is set, the door will open but the alarm will be activated if
the duress PIN code is entered. (duress PIN code is the code above the user PIN code
e.g. user code=8888 then duress code=8889).
Toggle Relay - If this option is set, then the door will remain open or closed on each PIN
entry for a Toggle User.
22
Set Guest Button on/off
On
23
Set Duress codes on/off
Off
24
Set Toggle Relay on/off
On
25
Set Door Forced Alarm on/off
On
26
Set Anti-Tail Gate on/off
Off
Manager User – If the Alarm Panel option is setup using the IO options then only the
Manager User will be granted access if the alarm is set.
The Manager User is the only user that can activate or deactivate the
Alarm Panel.The RED light Flashes to indicate the Alarm Panel is set.
The Manager User must press the ‘tick key’ and enter a PIN code to activate
the Alarm Panel or present a Manager User card twice.
To deactivate the Alarm Panel the Manager user enters a PIN code.If the Alarm
is deactivated then the Manager User operates as a standard user.
27
Set Constant Backlight on/off
On
28
Set Invalid PIN Lockout on/off
On (3 Retries)
Number of PIN Digits – The number of digits each User PIN will contain.(4 or 5 or 6).
The number of digits can not be reduced after a User PIN has been added.
If the number of PIN digits is increased then add leading Zeros to existing PIN’s.
E.G. if increasing PIN digits from 4 to 5 then existing PIN code ‘1234’ changes to
‘01234’
Relay Active Time – This is the amount of time the relay will remain active. Entering
0 for the relay active time will generate a 200millisecond pulse .
Ajar Alarm – This alarm will activate if the door is open longer than the Door Ajar Time.
Door Forced Alarm – This alarm will activate if the door contact is forced open.
Anti-Tail Gate – If this option is set, the door relay time is shortened to 2 seconds.
Guest Button - If this option is set, then the tick key can be used to sound the buzzer.
Silent Operation - If this option is set, then all audible tones are silenced.
Card Or Pin mode - allows both valid Cards or PIN codes to gain access.
Card And PIN mode - Only Users with a valid Card and an Associated PIN code gain access.
Card And Any PIN mode - Users with a valid Card and any valid PIN code gain access.
This mode allows a group PIN to be used with valid Cards.
1111
4 digit PIN (4,5,6 only)
6666
30
Change the Input and Output Options
0
31
Set Card Or PIN on/off
On
32
Set Card And PIN on/off
Off
33
Set Card And Any PIN on/off
Off
55
Restore Factory Default Settings
17
18 Administration Notes
Administration Notes
User Administrator
User
NO.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
User Name
19
Note: Duplicate this page for additional users
Card Number
PIN
User
NO.
User Name
Card Number
PIN