Download HAWK-I Template Reference Guide

Transcript
HAWK-I Template Reference Guide
VLT-MAN-ESO-14800-4076
17
Table 11: Parameters of HAWKI img obs GenericOffset
HAWKI img obs GenericOffset.tsf
To be specified:
Parameter
DET.DIT
DET.SATLEVEL
INS.FILT.NAME
SEQ.CATG
SEQ.FC.ST
SEQ.FILEID
SEQ.NDIT.LIST
SEQ.NEXPO
SEQ.NOFFSET
SEQ.OBSTYPE.LIST
SEQ.OFFSET.COORDS
SEQ.OFFSET1.LIST
SEQ.OFFSET2.LIST
SEQ.RETURN
SEQ.SHOW.GRAPH
Fixed values:
Parameter
DPR.CATG
DPR.TECH
Hidden
no
no
no
Label
DIT (secs)
SATLEVEL
Filter Name
no
yes
yes
no
no
no
no
no
no
no
no
yes
Range (Default)
1.6762..3600 (NODEFAULT)
-32768..40000 (25000)
Ks H J Y BrG NB2090 CH4 NB1190
NB1060 H2 (NODEFAULT)
TECHNICAL SCIENCE (SCIENCE)
T F (F)
(GenericOffset)
(NODEFAULT)
1..1000 (NODEFAULT)
1..1000 (NODEFAULT)
O S (NODEFAULT)
SKY DETECTOR (DETECTOR)
-600..600 (NODEFAULT)
-600..600 (NODEFAULT)
T F (T)
T F (T)
Hidden
yes
yes
Value
SCIENCE
IMAGE
Label
Data product category
Data product technique
Observation Category
Use flexure compensation?
Filename id
List of NDITs
Number of exposures per offset
Number of offsets
Observation type list, O/S
Offset coordinate type selection
List of X or RA offsets (arcsec)
List of Y or DEC offsets (arcsec)
Return to origin?
Show quick-look graphics?
The lists can have any length; however, having lists of different lengths can become extremely
confusing. It is good practice to use lists of equal length or lists with only one value if one
parameter is not changed. The total number of images taken by this template is SEQ.NEXPO×
SEQ.NOFFSET.
At the end of the template, the telescope is returned to the original position if the parameter
SEQ.RETURN is set to true (T). If not, the telescope is not moved at the end of the template.
The total integration time is defined, in seconds, by:
DIT × NEXPO ×
NOFFSET
X
NDIT(i)
1
where NDIT(i) are the elements of the List of NDIT.
4.2.5
Fast Photometry template
This template is used for windowed observations, and it is described in detailed in the user manual.
Briefly, the template is similar to the ISAACLW img acq FastPhot. The action sequence performed
by the template includes: 1. Preset the telescope, set up the instrument (no windowing at this
stage, the full field of view is shown on the RTD). 2. Move to the sky position, take a non-windowed
image, ask the operator to save it in the RTD and to turn on the sky subtraction 3. Take a nonwindowed image of the field of view, ask the operator if an adjustment is neces- sary. Note that
the adjustment here includes both the telescope pointing (and field of view orientation), and the
detector windowing parameters. At this stage the operator is expected to press the ”draw” button
that draws on the RTD the windowing as defined in the acqui- sition template. The operator can
modify it at any time from now on, but has to redraw to have the latest version shown on the
RTD. 4. If the operator gives a negative answer, the template acquires an image, saves it, and
then ends. Otherwise, an offset window is opened on the RTD to let the operator to de