Download ACS - Simulcast Solutions
Transcript
5 – Remote Control INT 17 18 Ø 96 ACS-160 Series & STL-160 Series T1 Multiplexer Installation & Operation Version 2.11, August 2011 ES 0 0 UAS 0 0 BES 0 0 SES 0 0 CSS 0 0 LOF 0 0 0 0 0 0 0 0 Table 5-25 describes the data in a REGISTERS? response. Table 5-25. ATT_STAT? and REGISTERS? Response Data Data Item Description Typical Values MEASURE SECS Measured Seconds - The number of seconds the integrated CSU has been accumulating CSU line performance statistics in the current 15 minute interval. This register can hold a maximum value of 900 (60 seconds per minute x 15 minutes = 900 seconds). Under normal operating conditions when the device is ANSI or AT&T compliant, measured seconds should be between 0 and 900. VALID INTERVALS Valid Intervals - The number of complete 15 minute intervals that the integrated CSU has accumulated CSU line performance data. This register can hold a maximum value of 96 (four 15 minute intervals per hour x 24 hours = 96 intervals). Under normal operating conditions, you should see a value between 0 and 96. ERRORED SECS (ES) Errored seconds - A second with one or more ESF error events, that is, one or more CRC6 error events or one or more OOFs (out of frame). Under normal operating conditions, you should not have any errored seconds. UNAVAIL SECS (UAS) Unavailable seconds - A count of one-second intervals during which service is unavailable. Under normal operating conditions, you should not have any unavailable seconds. BUR ERRD SECS (BES) Bursty errored seconds - A second with more than one, but less than 320 CRC6 error events. Under normal operating conditions, you should not have any BES seconds. SEV ERRD SECS (SES) Severely errored second - A second with 320 or more CRC6 error events OR one or more OOFs. Under normal operating conditions, you should not have any SEFE seconds. CTL SLIP SECS (CSS) Controlled slips seconds - The occurrence of a replication or deletion of a DS1 frame at the receiving terminal. A controlled slip may occur when there is a difference between the timing of a synchronous receiving terminal and the received signal. Under normal operating conditions, you should never have any SLIP errors. LOSS OF FRAME (LOF) Loss of frame - The occurrence of a DS1 terminal unable to synchronize on the DS1 signal for some interval. Under normal operating conditions, you should not have any loss of frame in a 24-hour period. Note: There are no commands available to clear the ATT_STAT? and REGISTERS? registers. Appendix A gives details on using ISiCL to configure the CM-5RTD common module’s delay feature. Harris Corporation Intraplex Products 5-45