Download NTM-M new.indd

Transcript
NEW
NEW TECHNOLOGY™ METER
NTM-M
Pat. Pend.
Current Loop, Signal or External Powered
Replaces: DB40 or Any 4” Switchboard Meter
>20’ Viewing Distance!
SEE NTM-N FOR
BAR
Build Your Own Part Number or
Receive a Quote at: http://www.
otekcorp.com/configurator/nts/
FEATURES:
*Automatic Tricolor Bar with Intensity Control
*4 Digits (9.9.9.9 or -1.9.9.9)
*Alarm with Run Time Stamp
*Self Diagnostics
*Isolated Serial I/O
*USB/RS485
*Configurable Bar Direction (Up/Down/Center Zero)/Pointer
*Only 100mW@5VDC!
*Intensity Control
* Math functions (+, -, x, √, ÷, X-Y tables, polynomials)
*Averaging: None to 255
*Addressable: 8 Characters
*Many Power Input Options
(External Powered Models Only)
* >30 Isolated Input Signals
*4 Relays or O.C.T.
*4-20mA/30V Output
*Ethernet
*μSD Flash Memory: 32 GB
*Lifetime Warranty
NOTHING
BEHIND
THE
PANEL
DESCRIPTION: The New Technology Meter (NTM) series combines over 40 years of experience with the latest ASIC uC and
ultra-efficient multicolor LED technology to bring you into 21st century. The NTM external power series features over 30 signal
conditioners (1” square) which are house in many industry’s standard packages to replace form, fit and function any analog or digital
panel meter. If not, we'll make it!
Our patented hardware and firmware gives you the highest reliability (we have a lifetime warranty) at the lowest cost, with features
such as: automatic (programmable) tricolor bargraph (like a traffic light); automatic signal fail detect (open or short); indication and
serial transmission with run time stamp and units ID, isolated retransmission (4-20mA), and universal power inputs (5-32VDC or
90-265VAC). The NTM Series offers several math functions such as X-Y tables, polynomials and log-anti-log functions.
The NTM signal and external power series also feature isolated
USB, RS485 or ethernet, open collector transistors (4/channel)
and SPDT relays (4/channel). You can tell us your custom needs
and we'll make it (or might already have it)!
The NTM-M is available in a loop (4-20mA), A.C. signal or
external power version. The external power versions can accommodate 4 relays, isolated DAC and power for the analog output
(per channel), include >30 signal conditioners and isolated input
power options, as well as ethernet and flash memory (μSD).
Standard factory set color changes are: red: <10, >90%, yellow:
<20, >80%, green: >20, <80% of F.S. Use digit 14, option 9 for
custom configuration (you can change it with simple commands).
NEW TECHNOLOGY METER BLOCK DIAGRAM/CHANNEL
CONTROLLER/DISPLAY ONLY
I
V
IN
A
IN
CURRENT
LOOP
(LOOP POWER)
AC/DC
V, A,W, Hz
(SIGNAL POWER)
•
DISPLAYS,
CPU,
SIGNAL DETECT,
KEEP ALIVE,
ISOLATORS
FOR ALARMS,
SERIAL I/O,
PWM,
ZERO/SPAN
SIGNAL
CONDITIONERS
REL AYS
O.C.T
ANALOG OUT
ETHERNET
USB/485
FLASH
MEMORY
O.C. T. (4)
RELAYS (4)
4-20mA OUT (1)
30V OUT (1)
RS485
USB/
ETHERNET
RS
485
(EXTERNAL POWER)
USB
5-32 VDC
90-265 VAC
POWER
SUPPLY
POWER
INPUT
DISPLAY ONLY
520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
THE PRODUCTS
All New Technology products share the same innovations proven by an independent NQA1 qualifier. The difference between the models is their mechanical features (see Block Diagram and mechanical drawings). Some can only be displays,
some can only have 1 channel, some can have relays, DACs, ethernet and flash memory, and some require an external
power source. But all products contain the New Technology, which consumes less than 1% of comparable digitals (1080mW for loop/signal powered versions) and approaches the power consumption of analog meters.
WHAT CAN YOU DO WITH OTEK’S NEW TECHNOLOGY?
Note on Otek’s Powerless™ Technology: If your signal cannot supply mW (~ 3V/3mA), contact us or use external
power models.
1. One Channel Models: -0,
-4, -B, -D, -F, -L, -M, -N, -P, -S
& -X: Implement any math
function, X-Y table (25 point),
polynomials (9th order), offset,
tare, zero, scale, log & antilogarithmic to affect the unit’s
display at will. Some examples are: change the display &
data using any combination as
commanded by your algorithm,
such as +/-/X/÷/√ or set a
variable or linearize the display
using X-Y tables or polynomials. This works well for odd
shape containers. You can also
change the reading from ◦F to
◦C or ◦K or compress/expand
the display (and data out) using
the log and antilog functions.
In addition, you can change the
factory default alarm pointers
and colors or delete them. Zero
& Span potentiometers are included for manual adjustment.
Note: Models -D and -F only
offer internally accessible USB
serial I/O for configuration and
mathematical functions. Use
digit 14 option 9 and specify
your custom calibration.
OTEK’s New Technology
series is only limited by your
needs and imagination. Just
give us a call at 520-7487900 or email us at sales@
otekcorp.com and give us the
challenge to develop the best
algorithm for your process.
2. Two Channel Models: -1,
-2, -3 and -5 through -9 &
-A: Note: Also available in
models with 3 or 4 channels.
Features include all those of the
single channel models and each
channel is 100% isolated from
each other. In addition, you can
add, subtract, multiply, divide,
find the square root between
channels. You can also use
one channel to monitor/control
the input signal and the second
channel to indicate deviation, differential such as PID,
alarm override or one channel
setpoint can be used to control
another channel function. You
can also use one channel as
a backup if the other channel
becomes disabled or use them
as volume & flow (√) monitors/
controllers. The New Technology two channel models
are also perfect as REM/RAD
indicators/controllers (also
see our RPM series with logantilog functions for radiation
monitoring).
Contact OTEK for algorithms
and formulas or any idea you
wish to share with our audiences via our Youtube or Facebook
page posts.
3. Three Channel Models:
-3, -5, -7, -8 and -A: Note:
Also available on 4 channel
models -5, -7 & -8. Otek’s
New Technology three channel models perform all the
functions outlined in #1 and
#2. Further, one channel can
indicate the input variable and
the other two channels can be
setpoint indicators/controllers
(Hi, Hi-Hi, Low and Low-Low
limits), or subject the input/
output to any mathematical
function or algorithm such as
PID or display the input vs.
output and derivative, or switch
scales when the input reaches a
limit/band such as for flow-volume-pressure or temperature.
Monitor Volts, Amps and Watts
AC or DC or any of 3 variables, including Hertz, lead/lag,
power factor, peak/valley or for
synchronizing of power lines
with the bipolar (center zero)
tricolor bargraph.
The New Technology series
brings Process Automation
Control (PAC) within your
reach and affordability. These
models are compatible with
any DCS/SCADA system using
their USB/RS485/Ethernet I/O
options and allow for ease of
interface with wireless systems.
4. Four Channel Models:
-5, -7 and -8: The four channel models offer all of the
functions outlined in #1, #2
and #3. However, with the additional channel available, the
New Technology barmeters
rival flatscreens with superior HMI/MMI functionality
and ease of viewing/analysis of any combination of 4
variables. For example, Volts/
Amps/Watts/Hertz or temperature/pressure/pH/humidity.
The four channel models can
also be used to monitor/control the product of the other 3
variables, making them ideal
for the petrochemical industry.
Data Logging? Some models
offer optional μSD memory to
record 24/7 anything available
via the serial I/O. Maximum
capacity (and growing) is 32
GB!
REDUNDANT CONTROL:
Because all channels are
100% isolated from each
other, you can use any
multi-channels model as a
redundant controller. If you
need the “Democratic vote,”
algorithm, contact OTEK or
see our Model TRC (Triple
Redundant Controller).
-2520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
Description, Notes & Order (Continued)
Digit 5, Serial I/O & Memory:
Settings: 8N1N, 1200-19,200 Baud,
ASCII.
Digit 5, Serial I/O: Option 0, USB:
Complies 100% with V2.0 and if digit
10, option 1 is selected (USB powered) then digit 5 must be option 0.
Digit 5, Option 1, RS485: Complies
with industry standard and requires
5VDC@<3mA and a terminating 330
Ohm resistor at first and last unit in the
BUS.
Digit 5, Option 2 Ethernet: Complies with 10 Base-T/100Base-TX
RJ45 up to 19,200 Baud. Maximum
power consumption is <300mA@5V
(1.5W).
Digit 5, Options 3 & 4: uSD Flash
Memory: Internal μSD flash memory
with up to 32 gigabytes capacity. You
can store selected data at-will via serial
command and download it as required.
A 32 GB card logging 3 times per second can hold approximately 4 year’s
worth of data.
Need a Transmitter?
See model TNT
Digit 6, Grade:
Industrial Grade (Options 0 or 1) is per
these published specifications. Grades
M and E per agreed specifications. Options M and E typically include EMI/RFI
shield all around and filtered connectors
to meet EPRI-TR-102323-R3 (requiring ~2” deeper case). OTEK will build
to certain nuclear or MIL-Standards but
testing and confirmation of compliance,
if required, will need to be done by third
party and at customer’s expense. Option
0 is 94VO plastic, option “I” is aluminium nickel plated to Mil-Specs. Typical
Mil-Specs: 461, 462, 169, 901, 801,
RTCA-160, I EEE344, etc.
Other Important Data:
Math Functions: +, -, x, ÷, √, Polynomials to 9th order, 25 Point X-Y table,
zero, offset, span and tare. You can
add, subtract, multiply, divide (etc.) one
channel to/from another channel and
display the result in the other channel
(i.e. V (Ch.1)xA(Ch.2)=W(Ch.3).
Signal Failure Alarm: Requires approximately 1 minute of normal (midscale) operation for it to alarm the
display and output the serial data after
the signal (Powerless™) has ceased.
Serial I/O: Setting: 8N1N, 1200-19,200
BAUD, 8 Character Address
PID: Programmable (best with >dual
channel models) automatic or manual
with external 10K Ohm potentiometer
(option 56).
High Quality: No matter their size or
number of channels all use the same
(SV & V) firmware, hardware and commands. No matter their grade (Industrial, Mil-Spec, Nuclear) they all carry a
lifetime warranty
Industrial Grade Common
Electrical Specifications
Input & Display:
*A/D: Accuracy, Linearity & Resolution: +/- 0.05% of F.S. 12 Bits,
Conversion Rate: 40/sec, Averaging:
0-255, zero, span, offset, tare, math
functions, 25 point X-Y tables and
polynomials (9th).
*Bargraph: 51 Automatic Tricolor
(R/Y/G) Segments
*Digits: Four Full Digits (9.9.9.9 &
-1.9.9.9).
*Typical Power Consumption of Display: 10-80mW@3.3V
*Temperature Coefficient:
+/-50PPM/°C
*Operating Temperature: -10 to +60;
Storage: -20 to +70°C
*CCMR: >90dB@50-60Hz
*Isolation: >500VDC to any other I/O
& P.S.
*Humidity: 5-95% RH non-condensing
*Front Panel: NEMA 3. NEMA 4x
on request.
*Failed Signal Detect: ~ 20 seconds
after > 1 minute “On” @50% of F.S.
Note 1: See page 13 of the master
catalog for environmental specs vs.
housing, bar length and digit size.
Note 2: E and M grades are the same
as Industrial unless otherwise specified.
ABOUT OUR INPUT
FAIL DETECTION
Only available on Powerless™
models. While in normal operation,
we store excess energy and use it to
power the NTM if and when the signal
fails (post mortem).
-3520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
INPUT SIGNAL SPECIFICATIONS (Digits 8 & 9)
Industrial Grade Common
Electrical Specifications
(Continued)
AVAILABLE ON EXTERNAL
POWER MODELS ONLY:
Outputs:
*Analog Output: Accuracy & Linearity: F.S.; 0.1 LSB, Range:
3-24mA (max. load: <1K Ohm).
*Analog Output Temperature Coefficient: +/-50PPM°C
*Analog Output Isolation To All
Other I/O & Power: >500VDC
*Relays: 4 Each/Channel (except
TNT, 2): SPDT Form C, 1A Max @
120VAC/30VDC resistive load only,
Contact Protection: 300VAC/DC on all
contacts. Speed: +40mS (main loop).
O.C.T. (Open Collector Transistors): VCE Max: 30VDC; Ice Max:
30mADC, Speed: +40 (main loop)
Note 1: Relays & O.C.T. have P.O.D.
(~100mS) and can be set for fail safe
operation (normally on).
Note 2: See Digit 11 for default set
points and User’s Manual for command set via serial control.
SEE CUSTOMIZED USER’S
MANUAL FOR SPECIFIC
CONNECTIONS AT:
http://www.otekcorp.com/
configurator/nts/
INPUT SIGNALS (Digits 8 & 9):
Options 01 through 14 for A. C. Signal Powered Only (Continued):
Note: Otek’s exclusive Input Fail
detect (open or short) is standard on all
Option 04, Hertz VAC: Burden:
inputs. Use option 29 and specify if
you want it disabled (also field configu- <100mW, Range: >30V<150V &
>30<500Hz; Accuracy & Linearity:
rable).
±0.2% of F.S.
Option 05-14: Same as options 01
IMPORTANT NOTE: Actual conthrough 04 above.
nection will vary. See the User’s
Manual or the NT Catalog for specific
connection information
Option 00 For Loop Power Only:
Option 00, Loop Powered: Burden:
< 4V; Range: 3-26mA; Accuracy &
Linearity: ±0.05% of F.S.
Options 01 through 14 for A. C. Signal Powered Only
Important Note: C.T. are sensitive
and limited to the secondary (output)
impedance. OTEK A.C. signal powered products present and input impedance of ~0.2 Ohms (~1v@5A). Make
sure your C.T. can drive a >0.3 Ohm
load without saturating or losing linearity. Contact Otek for assistance. Best
C.T. to use: >100:5.
Option 01, VAC (P.T.): Burden:
<100mW; Range: 30-150V/40-100Hz;
Accuracy & Linearity: ±0.2% of F.S.
Best operating range to specification:
90-150VAC
Option 02, 5 AMP A.C. (C.T.): Burden: <100mW; Range: .3-5A; Accuracy & Linearity: ±0.2% of F.S. Best
operating range to specification: 1-5
Amps.
Option 03, Watts A.C. (C.T. &
P.T.): Burden: <100mW, Range:
>30<750W/50-60Hz; Accuracy & Linearity: ±0.2% of F.S. at 90-140VAC &
1-5 AAC. Worst case: ±3% outside this
range. Best operating range to specification: 100-500 Watts.
AVAILABLE ON EXTERNAL
POWER ONLY
Option 20: 4-20mA: The burden on
the loop is only 0.5V@20mA (25 Ohm)
and you can use the math functions for
converting to flow, instantaneous or
totalizer.
Accuracy: +0.1% of F.S.
Options 21-24: VDC: Input impedance is 1 Mega Ohms on all VDC
ranges.
Input impedance 1M Ω
Range: Per Option
Accuracy & Linearity: ±0.05% of F.S.
Options 25 & 26, mADC: Since the
NTM is 2V full scale (2,000 Counts)
the “Shunt” resistors used are 100
Ohms for 10mA and 10 Ohms for
100mADC.
Input impedance 25: 50Ω; 26: 5Ω;
Accuracy & Linearity: ±0.05% of F.S.
Option 27, Watts DC:
VZin: 10M Ω/AZin: 1.0Ω, 5W
Range: 1W
Accuracy & Linearity: ±0.1% of F.S.
Option 28, Watts DC (1Vx1V):
VZin: 1M for both inputs
Range: 0-1V
Accuracy & Linearity: ±0.1% of F.S
-4520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
INPUT SIGNAL SPECIFICATIONS (Digits 8 & 9)
AVAILABLE ON EXTERNAL POWER MODELS ONLY
Option 29: Custom: Use this option
to describe any custom input, scale or
modification to the NTM and contact
us for feasibility and cost.
Option 40 (120VACx5AAC C.T.):
Zin: 1M for V & 0.04Ω for I
Range: 0-750W
Accuracy & Linearity: ±0.2% of F.S.
Options 30-34, Volts RMS: Here we Note: Option 40 (120V/5A) includes
use a True RMS-DC Converter for
the shunt (0.04 Ohms/20W) on conaccurate (+ 0.1%) measurement of sine nector only for 5A C.T.
waves up to 10KHz. For 10-20KHz
Options 41-44, Hertz: We use an F-V
and SCR accuracy is + 1%.
to accept frequencies up to 20KHz
and amplitudes from 1-400V peak or
VRMS: Zin: 1MΩ
dry contact or open collector transistor
Range; per options;
(O.C.T.). For 50 to 440 Hz power line
Accuracy & Linearity: ±0.1% of F.S.
frequency measurement, use Option #
Options 35-37, Amps RMS: We use a “44.”
True RMS-DC Converter for accurate
(+ 0.1%) measurement of sine waves
Option 41 (10KHz/5V Logic):
up to 10KHz. For 10-20KHz and SCR Zin: 1M
accuracy is + 1%.
Range: 30-10KHz
Accuracy & Linearity: ±0.1% of F.S.
Zin: 35 (0.1A): 2Ω; 36 (1A): 0.2Ω;
37 (5A): 0.04Ω; Range: Per option
Option 42 (120V, 40-100Hz):
Accuracy & Linearity: ±0.1% of F. S.
Zin: 1M
Range: 50-150VC/30-100Hz
Options 38 & 40, Watts RMS:
Accuracy & Linearity: ±0.1% of F.S.
Here we use a True RMS-DC Converter for accurate (+ 0.1%) measureOption 43 (240V, 30-100Hz):
ment of sine waves up to 10KHz. For Zin 1 M; Range: 100-260V/30-100Hz
10-20KHz and SCR accuracy is + 1%. Accuracy & Linearity: ±0.1% of F.S.
Input impedances vs. range are the
same as for VDC & mADC ranges.
Option 44 (120V, 500 Hz):
Zin: 1 M
Option 38 (1Vx1VAC):
Range: 50-150V/300-500Hz
Zin: 1MΩ for both inputs Range: 1V Accuracy & Linearity: ±0.2% of F.S.
RMS
Accuracy & Linearity: ±0.2% of F.S.
Note: Always use P.T. & C. T. for options 33, 34, 40, 42, 43 & 44.
Option 45: Strain-Gage (>300 < 4K
Ohm): These are typically "Monolithic" S-G that require constant voltage (preferably) excitation. We use
4.096V for high stability and accuracy. Use option 29 and specify your
S-G sensitivity and the NTM display
at Zero and Full Scale.
Excitation: 4.096V, 50 PPM/C
Range: ±300-4K Ω
Accuracy & Linearity: ±0.1% of F.S.
Note on S-G: Some S-G offer +/1VDC or 4-20mA condition output.
Use Option 29 and specify.
Option 47: RTD (PT100): Note: For
options 47 & 48 you can change °C to
°F and RTD type via serial port.
We excite your 2 , 3 or 4 wire RTD
with 200μA to avoid the "self heating"
effect. The range of the NTM is the
same as your RTD typically -2000C
to +8000C (-328 + 15620F). You can
place the decimal point at will (typically -200.0 to 800.0. The PT100 has
a temperature coefficient of 0.00385
Ohms/Ohm/0C. (For legacy 0.00392
TC (known as ANSI 392) contact
OTEK and use Option "29".
Accuracy: +0.5% of F.S. plus sensor's
error.
Note: For 2 wire, jump - S to -E and
+S to +E. For 3 wire only jump -S to
-E.
-5520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
INPUT SIGNAL SPECIFICATIONS (Digits 8 & 9)
AVAILABLE ON EXTERNAL POWER MODELS ONLY
Option 48: RTD (PT1000): Same as
PT100 except it is 1000 Ohms at 00C
instead of 100 Ohms @ 00C. The same
technique is used for copper RTD (10
Ohm), contact OTEK. Same connection as Option 47 apply.
Accuracy: +0.5% of F.S. plus sensor's
error.
Note: For long distances (> 300’)
use a 4-20mA transmitter such as our
model TNT from our New Technology series.
Option 50: Thermocouple (Type
J): This TC has a range of -210 to +
7600C (-350 + 13900F). Its color is
white (+) and Red (-), cold junction
(CJ) is at the connector. Make sure the
connections from the NTM and your
TC are as close to the NTM entrance
as possible to avoid errors. If you
short out the NTM's +TC & -TC together, the NTM will read the ambient
temperature at the junction due to its
built-in C.J.C.
Note: You can change °C to F and TC
type via serial port.
Option 53: pH (Acidity): We use a
FET input (1015) amplifier and calibrate
the NTM for 0-14.00 pH using the
Industry's standard + 413 mV = + 7pH
co-efficient. Note: Not temperature
compensated, contact OTEK for auto
temperature compensation.
Accuracy: +0.05% of F.S.
Option 54: ORP (Oxygen Reduction
Potential): Our FET amplifier (109)
accepts the industry standard 2000mV
F.S. of the probe and the NTM displays
it in % (0-100.0%).
Accuracy: +0.05% of F.S.
Option 55: %RH: This conditioner is
designed to interface to a typical (capacitance type) 2-3 pF/% of RH made
by several manufacturers. Use Option
"29" and contact OTEK to specify your
sensor's specifications.
Accuracy: + 0.05% RH of signal input.
Digit 10 (Power Input):
LOOP & SIGNAL POWER ONLY:
Digit 10, Option 0, Powerless, No
Power Required: The Input Fail detect/Alarm (patent pending) flashes the
display “Input Fail” () and
transmits this serial message for ~20
seconds, after which it will cease. This
feature is available in all
Powerless™ models. If desired on
powered models, use option 9 on Digit
14 and specify “input fail detection).
Signal Fail Requirement: Unit must be
“On” for at least 1 minute at >50% of
full scale for it to operate.
EXTERNAL POWER ONLY:
Digit 10, Option 1, USB Powered:
The NTM series requires >.1<1.5
Watts/Channel (worst case, fully
loaded) meaning that you can power it
through the USB port, but this option
eliminates the isolation from USB to
Option 56 Resistance (0-10K Ohm):
input signal. Analog output remains
Want a simple 4-20mA transmitter? Just isolated contact OTEK for more details
connect a 10K Ohm (others on request) or use options 2-4.
potentiometer to the NTM and control
any 4-20mA input valve, motor, transDigit 10, Option 2, 5VDC: 5VDC is
Accuracy: + 20 F.S. of signal input.
ducer, etc. Accuracy & Linearity is
used to drive the relays (<50mA/relay)
±0.1%
of
F.
S.
Standard
Calibration:
and/or the DAC via internal isolated
Option 51: TC (Type K): This is yel0-10K
Ohms=4-20mA.
Use
option
#29
5-30VDC-DC (<200mA). If you order
low (+) and red (-) and has a range of
and
specify
your
calibration.
Ideal
for
0
0
relays and analog out, you will need
-270 + 1370 C (-440 + 2500 F). The
linear
transducers.
~300mA/channel. This option is also
same notes as Option 50 apply.
0
isolated from the input signal.
Accuracy: + 1 F.S. of signal input
Option 58: Serial Input Remote
Display/Controller: Here you can
Digit 10, Option 3, 7-32VDC: Same
Option 52: TC (Type T): This blue (+)
use the unit as a remote display
0
as option 2 but with wide input range
and red (-) TC has the range of -270
& controller with modified ASCII
0
0
of 7-32VDC. Efficiency: >80%.
+ 400 C (-440 + 750 F). Same notes as
to alpha-numeric display for DCS
Option 50 apply.
SCADA, PLC systems.
Digit 10, Option 4, 90-265VAC: This
0
option accepts 50-60Hz. For 100Accuracy: + 2 F.S. of signal input.
See the user’s manual for simple
300VDC or 400 Hz, use Digit 10, opcommands to use the NTM in PAC
tion 9 and specify. Efficiency: >80%.
applications.
-6520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
Description, Notes & Order (Continued)
Digit 11 (Control Outputs):
AVAILABLE ON EXTERNAL
POWER ONLY
Digit 11 (Control Outputs): (Contin- Digit 12 (Analog /Power Output):
ued)
Digit 12, Analog Output, Option 1:
See commands in the user’s manual to (Continued)
customize your bargraph colors.
Digit 11, Option 1: Collector Transistors (O.C.T.): They are NOT isolated
from each other (common emitter) but
are isolated between channels and can
sink a maximum of 30 mA and sustain
a maximum of 30VCE (the O.C.T. are
normally used to drive the S.S.R.).
When you order option 2 (Relays),
we use the O.C.T. to drive the relays.
Inductive loads must be attenuated by
the user.
For other configurations , use option
9 on Digit 14 (field configurable).
Analog Output External Control
Max power consumption per relay:
(Use Option 9 and specify): A)
50mA@5VDC (0.25W). See Digit 14. 0-100mVDC in=4-20mA out; B) 0-10K
Ohm in=4-20mA out; C) Use options
External Control: You can control
58, 68, 78 or 88 and control it via serial
the O.C.T./Relays via the serial port
port.
at will with simple commands. They
don’t have to be assigned to the bar
Digit 12, 30 VDC Out, Option 2:
colors/set points, but are by default.
Use this option to power your 4-20mA
transmitter or other transducer. MaxiNotes:
mum current is 25mADC. It’s isolated
NOTE: You can use the internal iso1. Digit 11 is governed by Digit 7 (#
and is the same power source we use
lated 5VDC power to drive loads with
of
Channels)
&
Digit
4
(Housing).
for 4-20mA out. Power consumption:
the O.C.T. Total maximum current
Reason: Digit 11 can NOT have more 200mA@5VDC (1W)/channel.
available is 50mADC.
channels than permitted by Digit 7 or it
cannot fit in the housing (Digit 4).
1. This digit 12 is governed by digits 4
Digit 11, Option 2: Relays: are
(Housing) & 7 (# of Channels). ReaS.P.D.T. (1C) and can switch maximum
son: Digit 12 cannot have more outputs
2. Some models only offer 2 relays
resistive loads of 1 Amp @ 120 VAC
than input channels (Digit 7), which is
or 30 VDC. They include 300V varis- (see the ordering information). You
governed by Digit 4 (Housings).
can assign any relay to any limit.
tors at their contacts.
Digit 13 (Scale Plate):
Digit
12
(Analog
/Power
Output):
AUTOMATIC BAR COLORS:
Digit 13, Scale Plate: Option 0 is a
AVAILABLE
ON
EXTERNAL
standard scale plate that reads 0-100%.
Limits/Colors Factory default (% of
POWER ONLY
Use option 9 for custom printing and
Full Scale): Also see digit 14.
contact Otek.
Digit
12,
Analog
Output,
Option
1:
Low-Low Limit (<10%): Red Bar,
Digit 14 (Range/Calibration):
This isolated output is factory set to
OCT1/K1 “ON”
follow the input (0-F.S. in=4-20 out)
Low Limit (<20%): Yellow Bar,
0= Factory Default: 0-Full Scale Input
but can also be set for other outputs or
OCT2/K2 “ON”
=0-100% bar and 0-100.0 digits. Colors:
serially controlled by simple comHigh Limit (>80%): Yellow Bar,
<10>90%: Red; <20>80%: Yellow;
mands via the serial port.
OCT3/K3 “ON”
>20<80%: Green. Use Option 9 (cusHi-Hi Limit (>90%): Red Bar,
tom) and contact Otek. Also see ConFor other outputs, use option 9 and
OCT4/K4 “ON”
trol Outputs (Digit 11).
specify, including reverse scale (420=20-4), bipolar and PID. Power
Safe Area (>20<80%): Green bar
Bargraph Default: 0-full scale=
consumption: 200mA@5VDC (1W).
will follow signal input and if outside
0-100%. You can program it for single
the limits, it will change its color to the
pointer, or three or five bars via the selimit’s color (yellow or red).
rial port.
-7520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M LOOP POWER VERSION ORDERING INFORMATION 5-18-15
NOTE:
1. USB I/O is powered
by VUSB. RS485 requires 5V@~3mA.
2. Otek will build to
certain nuclear or MILStandards but testing
and confirmation of
compliance, if required,
will need to be done
by a third party and at
customer’s expense.
1 CHANNEL LOOP POWERED DISPLAY
NTM-M
OTEKS HI-Q123/TBS (4” x 4”) Switchboard Case
5
6 7
MODEL NTM-M
-
SERIAL I/O (1)
0......................................USB
1...................................RS485
9.....Custom (Contact OTEK)
GRADE & CASE (2)*
0.................................................Industrial & Plastic
I...................................................Industrial & Metal
M.................To Mil-Spec & Metal (Contact OTEK)
E.............To Epri-Nuclear & Metal (Contact OTEK)
9........................................Custom (Contact OTEK)
*Grades E, M & 9
might require an
N.R.E. fee.
# OF CHANNELS
1........................................One
9.......Custom (Contact OTEK)
INPUT SIGNAL
00...........4-20mA, All Channels=Input, Loop Power
8 9
0
0
10 11 12 13 14
0
-
0
0
RANGE/CALIBRATION
0..................................Standard
9........Custom (Contact OTEK)
SCALE PLATE
0.................Standard (0-100%)
9.......Custom (Contact OTEK)
ANALOG/POWER OUTPUT
0..........................................None
CONTROL OUTPUTS
0...........................................None
POWER INPUT
0.........................................None
NTM-M SIGNAL POWER VERSION ORDERING INFORMATION 5-18-15
NOTE:
1 CHANNEL SIGNAL POWERED DISPLAY
1. USB I/O is powered by
OTEKS HI-Q123/TBS (4” x 4”) Case
VUSB. RS485 requires
5V@~3mA.
2. Otek will build to certain
5 6 7 8 9 10 11 12 13 14
nuclear or MIL-Standards but
0 - 0 0
NTM-M
testing and confirmation of
RANGE/CALIBRATION
SERIAL I/O (1)
0..................................Standard
compliance, if required, will
0......................................USB
9........Custom (Contact OTEK)
need to be done by a third party
1...................................RS485
9.....Custom (Contact OTEK)
and at customer’s expense.
SCALE PLATE
0.................Standard (0-100%)
3. For other ranges (i.e.
GRADE & CASE (2)*
9.......Custom (Contact OTEK)
400 Hz) use option 9 and 0.............................................Industrial & Plastic
specify.
I...............................................Industrial & Metal
ANALOG/POWER OUTPUT
NTM-M
M.............To Mil-Spec & Metal (Contact OTEK)
E.......To Epri- Nuclear & Metal (Contact OTEK)
9....................................Custom (Contact OTEK)
*Grades E, M & 9
might require an
N.R.E. fee.
# OF CHANNELS
1........................................One
9.......Custom (Contact OTEK)
0..........................................None
CONTROL OUTPUTS
0...........................................None
POWER INPUT
0..........Powerless™ (No Power)
INPUT SIGNAL (3)
01.............................................Volts A.C.
02.........................................5 Amps A.C.
03............................................Watts A.C.
04.......................................Hertz A.C.V.
09....................Custom (Contact OTEK)
-8520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M
EXTERNAL POWER ORDERING INFORMATION 5-18-15
NOTE: Please READ BEFORE building part number:
1. If digit 10 is option 1, then digit
5 must be option 0 or 3. USB I/O is
powered by VBUS (3mA). RS485
requires 5V@~3mA.
1 CHANNEL EXTERNAL POWERED CONTROLLER
5
6
7
NTM-M
-
8 9 10
-
11 12 13 14
RANGE/CALIBRATION
0..................................Standard
9........Custom (Contact OTEK)
SERIAL I/O (1)
0............................................USB
1.........................................RS485
2......................................Ethernet
3................USB & μSD Memory
4.............RS485 & μSD Memory
9............Custom (Contact OTEK)
SCALE PLATE
0.................Standard (0-100%)
9.......Custom (Contact OTEK)
ANALOG/POWER OUTPUT
0................................................None
1....CH. 1........................4-20mA Out
2....CH. 1..............................30V Out
9..................Custom (Contact OTEK)
GRADE (2)*
0..........................................Industrial & Plastic
I............................................Industrial & Metal
M....To Mil-Spec & Metal (Contact OTEK)
E.......To EPRI-Nuclear & Metal (Contact OTEK)
9...........................Custom (Contact OTEK)
*Grades E, M & 9
might require an
N.R.E. fee.
NTM-M
OTEKS HI-Q123/TBS (4” x 4”) Case
CONTROL OUTPUTS
0...........................................None
1....CH. 1.....................O.C.T. (4)
2....CH. 1.....................Relays (4)
9...........Custom (Contact OTEK)
# OF CHANNELS
1......................................One
9......Custom (Contact OTEK)
INPUT SIGNAL (3)
mAll Channels Same Input)
21...............................................100mV DC F.S.
22.......................................................1VDC F.S.
23.....................................................10VDC F.S.
24..................................................100VDC F. S.
25.................................................10mADC F. S.
26................................................100mADC F.S.
27...................................Watts DC (1Vx1A) F.S.
28...................................Watts DC (1Vx1V) F.S.
29...............................Custom (Contact OTEK)
30...............................................0.1V RMS F. S.
31...................................................1V RMS F.S.
32.................................................10V RMS F.S.
33..............................................150V RMS F.S.
34.............................................250 V RMS F.S.
35...............................................0.1A RMS F.S.
36..................................................1A RMS F.S.
37...................................................5A RMS F.S.
38...............................W RMS (1Vx1VAC) F.S.
40..........................W RMS (120Vx5A AC) F. S.
41.........................Hertz (10KHz/5V Logic) F.S.
42....................Hertz (120VAC/40-100 Hz) F.S.
43...........................Hertz (240VAC/30-100 Hz)
44..........................Hertz (120VAC/500 Hz) F.S.
45........................Strain-Gage (≥300<4K Ohm)
47..................................................RTD (PT100)
48................................................RTD (PT1000)
50.....................................................TC (Type J)
51....................................................TC (Type K)
52....................................................TC (Type T)
53...................................................pH (0-14.00)
54.......................................ORP (0-2000mVDC)
55...................................% RH (Specify Sensor)
56......................................Resistance (0-10K
None (Serial Input Remote Meter)
POWER INPUT (1)
1....................Non-Isolated USB
2..........................Isolated 5VDC
3....................Isolated 7-32VDC
4.................Isolated 90-265VAC
9..........Custom (Contact OTEK)
-M or -N? The Difference:
-“N”
-M has solid .4”
segments. N has
three dotted
segments.
That’s all!
-“M”
NOTES (Continued):
2. Otek will build to certain nuclear or MILStandards but testing and confirmation of compliance, if required, will need to be done by a third
party and at customer’s expense.
3. For 400 Hz line, use option 29 and specify input. Peak & Hold to 50KHz function on request.
-9520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA
NTM-M MECHANICALS AND TYPICAL CONNECTIONS
NTM-M/-N MECHANICAL INFORMATION
0.125"R
(4 PL.)
4.35"
NOTES:
1. ANSI 4"(3.375") CASE CAN
ALSO BE MOUNTED IN 1/4
DIN PANEL CUTOUT.
4.38"
<1.25"
0.70"
3.375" (85.2MM) SQR.
8-32x1"
(4 PL)
3.50"D
2. CONNECTORS AND 3.375"
STUDS SPACING MEET ANSI39.1
STANDARD FOR SWITCHBOARD
METERS. J1 FALLS WITHIN
EXISTING "BARREL" CUTOUT.
CONNECTORS
4.35"
4

CL
& ADJUSTMENT
AREA
3"H X 2.5"W
CENTERED
3. WIRE: 26-16GA
4. SHIELDED VERSIONS WILL
EXTEND ~2” BEHIND THE
PANEL.
5. PLASTIC IS 1” THICK;
METAL IS 0.7” THICK.
REAR VIEW
SIDE VIEW
FRONT VIEW
F#87TBSME
NTM-M & N TYPICAL CONNECTION INFORMATION
SEE CUSTOMIZED USER’S MANUAL FOR SPECIFIC CONNECTIONS AT:
http://www.otekcorp.com/configurator/nts/
NTM-M & N TYPICAL CONNECTIONS
NTM-M & -N TYPICAL CONNECTIONS
EXTERNALLY POWERED MODELS
LOOP POWER/5 V.P./USB POWERED MODELS
(WITH CONTROL OUTPUTS)
NTM-M & -N TYPICAL CONNECTIONS
SIGNAL POWER MODELS
SPAN
ZERO
ST1
RS485 (ST4):
1: +5 V D.C.
2: D- (B)
3: D+ (A)
4. GROUND
SERIAL I/O
1
2
3
4
USB
ST4
ST5
ST5, DAC/30V OUT:
1: +LOOP/30V OUT
2: -LOOP/0V OUT
3: CUSTOM INPUT
1
2
3
DAC/30V
OUT
1
2
3
4
ST2
1
2
3
4
5
6
7
8
9
10
11
12
ST3
1
2
ST1
ST1, INPUT
SIGNALS:
SEE TEXT
ON MANUAL
ST2A: RELAYS/O.C.T.:
1: K1 N.O./5V OUT FOR O.C.T.
2: K1 COM./C. EMM. FOR O.C.T.
3: K1 N.C./O.C.T. 1
4: K2 N.O./O.C.T. 2
5: K2 COM./O.C.T. 3
6: K2 N.C./O.C.T. 4
7: K3 N.O.
8: K3 COM.
9: K3 N.C.
10: K4 N.O.
11: K4 COM
12: K4 N.C.
MAX 5 V OUT: 50mA.
1
2
3
4
SPAN
DO NOT
TOUCH
ZERO
RS485 (ST4):
1: +5 V D.C.
2: D- (B)
3: D+ (A)
4. GROUND
USB
SERIAL I/O
ST4
1
2
3
4
RS485
ST3, POWER IN:
1: V+/V A.C. H
2: V-/V A.C. L
NOTE: SERIAL CAN BE EITHER USB OR ST4.
WARNING!
H.V.
IN THIS
SECTION.
INPUT:
1: V A.C. HIGH
2: V A.C. LOW
3: A A.C. HIGH
4. A A.C. LOW
RS485 (ST4):
1: +5 V D.C.
2: D- (B)
3: D+ (A)
4. GROUND
12 3 4
ST4
ZERO
CH A
USB
SERIAL I/O
1
ST1A 2
3
4
INPUT:
1: V A.C. HIGH
2: V A.C. LOW
3: A A.C. HIGH
4. A A.C. LOW
SPAN
NOTE: SERIAL ON EITHER USB OR ST4.
NOTE: SERIAL USES EITHER USB OR ST4.
-10520-748-7900
FAX: 520-790-2808
E-MAIL: sales@otekcorp.com
http://www.otekcorp.com
4016 E. TENNESSEE ST.
TUCSON, AZ. 85714 U.S.A.
SINCE 1974
MADE
IN
USA