Download phyCORE-167/phyCORE

Transcript
phyCORE-167CR/167CS
2. The CAN transceiver populating the phyCORE-167CS is disabled;
CAN signals generated by the CAN transceiver (U3) on the
Development Board extending to connector P2B without galvanic
seperation:
Jumper
JP33
Setting
2+4
JP34
2+3
JP14
2+3
1+2
JP15
2+3
1+2
JP13
open
JP18
open
JP29
open
Table 42:
5
9
4
8
3
7
2
6
1
Figure 21:
1:
2:
3:
4:
78
Description
Pin 2 of the DB-9 plug P2B is connected to CAN-L1
from on-board transceiver on the phyCORE module
Pin 7 of the DB-9 plug P2B is connected to CAN-H1
from on-board transceiver on the phyCORE module
Input at opto-coupler U6 on the Development Board
connected to CAN2_Tx (P4.71) of the C167CS
Input at opto-coupler U6 on the Development Board
connected to CAN2_Tx (P8.32) of the C167CS
Output at opto-coupler U7 on the Development Board
connected to CAN2_Rx (P4.43) of the C67CS
Output at opto-coupler U7 on the Development Board
connected to CAN2_Rx (P8.24) of the C167CS
CAN transceiver and opto-coupler on the Development
Board disconnected from supply voltage
No GND potential at CAN transceiver and opto-coupler
on the phyCORE Development Board HD200
No power supply via CAN bus
Jumper Configuration for CAN Plug P2B using the CAN Transceiver
on the phyCORE-167CS
Pin 3:
Pin 7:
Pin 2:
Pin 6:
GND (Development Board Ground)
CAN-H0 (not galvanically separated)
CAN-L0 (not galvanically separated)
GND (Development Board Ground
Pin Assignment of the DB-9 Plug P2B (CAN Transceiver on
Development Board, only with C167CS)
Port P4.7 is the default port for CAN2_Tx (standard).
Port P8.3 is the alternative port for CAN2_Tx (see C167CS User‘s Manual/Data Sheet).
Port P4.4 is the default port for CAN2_Rx (standard).
Port P8.2 is the alternative port for CAN2_Rx (see C167CS User‘s Manual/Data Sheet).
 PHYTEC Meßtechnik GmbH 2002