Download M20 User manual
Transcript
Information examples -Initial the HyperTerminal -Initial the MS -AT Command AT+IPR=? +IPR:(),(75,150,300,600,1200,2400,4800,7200,9600,14400,19200,28800,33900, 38400,57600,115200) OK AT+IPR? +IPR: 115200 OK DTE-DCE character framing (+ICF) Table: Syntax (+ICF) Command Possible response(s) +ICF=[<format>[,<parity>]] +ICF? +ICF:<format>,<parity> +ICF=? +ICF:(list of supported <format> values),(list of supported <parity> values) Description This extended-format compound parameter is used to determine the local serial port start-stop (asynchronous) character framing that the DCE shall use while accepting DTE commands and while transmitting information text and result code, if this is not automatically determined; IPR 0 forces ICF 0 (see IPR, 6.2.10). Note that the definition of fixed character format for OnLine Data State is for further study. format determines the number of bits in the data bits, the presence of a parity bit, and the number of stop bits in the start-stop frame. <parity> determines how the parity bit is generated and checked, if present. Defined values See Table 5. ©2004 BenQ Corporation. M22 AT COMMAND LIST Confidential Property 148 Version: 0.3.0 – 2004/6/9