GENERAL ___________________________________________________________
Scope of delivery
1 hybrid amplifier PAMP 4
1 screened lead for the voltage supply
5 IEC coaxial right -angle plugs with covers
1 user manual
Technical data
This product conforms with the requirements of
the 73/23/EC and 89/336/EC guidelines of the
European Council.
The standards EN 50083-2, EN 50083-2/A1,
EN 50083-1 and EN 60065 required for the
CE certification are kept to.
RF input
Input frequency range:
Input impedance:
Input level:
Input level control range:
Amplification:
Noise factor:
47 MHz ... 862 MHz
75 Ω
max. 86 dBµV
0 to – 20 dB
typ. 37 dB
about 7 dB
RF output
Output frequency range:
Output impedance:
Measurement output:
47 MHz ... 862 MHz
75 Ω
– 30dB
Max. output level at 862 MHz
60 dB – IMA 3rd order1):
60 dB – CTBA (CENELEC) 2):
60 dB – CSOA (CENELEC) 3):
Output level control range:
Equalization:
Push-pull amplifier, can be deactivated:
123 dBµV (– 8 dBµV)
110 dBµV (– 8 dBµV)
113 dBµV (– 8 dBµV)
0 to – 20 dB
0 to – 20 dB
115 dBµV
Power supply:
Power consumption:
Ambient temperature:
––, +
––
+ 24 V --– 4 V --about 15 Watt
–10°C to +50°C
4 IEC sockets, female
1 IEC socket, female
1 IEC socket, female
1) according to EN 50083 Part 5, (DIN 45004 B)
2) according to EN 50083 Part 3, CTBA at 60 dB – IMA, CENELEC norm
norm with 42 channels
3) according to EN 50083 Part 3, CSOA at 60 dB – IMA, CENELEC norm
with 42 channels
ENGLISH
Connectors and controls
RF inputs 1, 2, 3, 4:
– 1 level control per input
RF measurement output:
RF output:
– with output level control
– with EQUALIZATION control