DB15 NOTE: GPS GROUND MUST BE
PLUG COMMON TO AIRCRAFT GROUND
GPS TX 9
RESET 1 6
RESET 2 13
EXTERNAL ON 14
GSW0 5
GSW1 12
LIGHT 2
GROUND 7
AUDIO POWER 8
BLK NOTE: N/C PINS RED+
FROM GPS DATA OUTPUT
REMOTE SWITCH
MOLEX PLUG
5
2
7
1
3
8
6
9
1, 3, 4, 10, 11, 13
HORN
452-6505
UN-SWITCHED
POWER
+14V
+28V
NOTE: PINS 6 & 9
ARE INTERNALLY
TIED WITHIN THE
REMOTE SWITCH
ASSEMBLY
Figure 4-3: Metal Airframe Installation w/Unshielded Harness
With Harness Ground Conductor
DB15
PLUG
GPS RS-232 TX 9
RESET 1 6
RESET 2 13
EXTERNAL ON 14
GSW0 5
GSW1 12
LIGHT 2
GROUND 7
AUDIO POWER 8
NOTE: N/C PINS
1, 3, 4, 10, 11, 13
NOTE: GPS GROUND MUST BE
COMMON TO AIRCRAFT GROUND.
FROM GPS DATA OUTPUT
REMOTE SWITCH
MOLEX PLUG
CABLE
SHIELD
SHIELD USED AS
GROUND WIRE
RED+
BLK-
HORN
452-6505
5
2
7
1
3
8
6
9
UN-SWITCHED
POWER
+14V
+28V
NOTE: PINS 6 & 9
ARE INTERNALLY
TIED.
NOTE: IF UNSHIELDED HARNESS IS INSTALLED, A
GROUND CONDUCTOR BETWEEN DB15 PLUG PIN 7
AND MOLEX PLUG PIN 6 IS REQUIRED
Figure 4-4: Composite Airframe w/Shielded Harness
Shield Used as the Ground Conductor (See Diagram Note)
4.3.3
GPS Data Output Interface with Remote Switch Harness
Referring to the wiring diagrams in Subsection 4.3.2, install a GPS data output
conductor as follows:
1. Run a minimum 24-AWG conductor from the GPS data output to the remote switch
harness DB15 plug.
2. Connect the GPS end of the data conductor in accordance with the GPS
manufacturer’s recommendations.
3. Disconnect the harness DB15 plug from the ELT.
4. Perform the following steps if the back shell of the DB15 plug has not been filled
with RTV or other potting compound. If the plug back shell is potted, proceed to
Step 5.
a) Strip the insulation from the conductor back approximately 1/8” (0.125”).
b) Solder the conductor into the Pin 9 solder cup of the plug in accordance with
the wiring diagrams shown in Subsection 4.3.2.
Page 12 of 21