Download ATPL230A USER GUIDE

Transcript
Introduction
ATPL230A-EK is an evaluation kit for the ATPL230A modem for Power Line Communication from
Atmel® Corporation. ATPL230A is a power line communications base band modem, compliant with the
PHY layer of PRIME (Power Line Intelligent Metering Evolution) specification.
ATPL230AMB is PLC multi-purpose modem board based on the ATPL230A transceiver and on
Atmel®|Smart™ SAM4C ARM® Cortex™ M4 microcontroller. This development board provides a full
featured platform to develop a complete communications system over Power Line Communication
technology.
This guide describes how to use the kit and get start with it.
Contents
 Welcome letter that presents
evaluation kit and the contents.
 Boards:
you
the
 Cables:


Two micro A/B-type USB cables.
Two power cord cables IEC320C8.

Two
ATPL230AMBv4
boards.
modem

Two ATPLCOUP001v1
boards.
coupling


Two voltage jumper with pitch
5.08mm.
Two ATPLCOUP006v1
boards.
coupling

Two erase jumper with pitch
2.54mm.
 Jumpers:
Features
2

ATPL230A is a compact and high-efficient device for a wide range of Smart Grid applications such
as Smart Metering (Smart Meters and Data Concentrators), Lighting, Industrial/Home Automation,
Home and Building Energy Management Systems, Solar Energy and Plug-in Hybrid Electric
Vehicle (PHEV) Charging Stations.

ATPL230A PRIME device includes enhanced features such as additional robust modes and
frequency band extension. ATPL230A is able to operate in independently selectable transmission
bands up to 472 kHz, achieving baud rates ranging from 5.4 kbps up to 128.6 kbps.

ATPL230A has been conceived to be bundled with an external Atmel MCU. ATPL230AMB modem
board mounts the ATPL230A transceiver and on SAM4C ARM Cortex M4 microcontroller. This
development board provides a full featured platform to develop a complete communications
system over Power Line Communication technology.

Evaluation platform performance for the Atmel ATPL230A to develop a complete communications
system based on PLC technology:
–
Channel characterization.
–
Noise level measurement.
–
Sensitivity level measurement.
–
Maximum reachable distance.
–
Power consumption.
–
Possibility to verify the different standard frequency bands complying with the existing
regulations (CENELEC, FCC, ARIB) setting the different PLC couplings boards.
–
A transformer lets you supplied the board with universal 115-230 VAC 50-60 Hz power input.