70
Map3D User's Manual
Enter the following:
Job Title: Coal Pillar Model
All parameters can be left at there default values except the stress tolerance, element length and
grid spacing.
Stress Tolerance: 0.01 MPa
should be set to approximately 0.1% of the far field stress state. This ensures that during solution,
the surface stresses will be calculated with 0.01 MPa numerical accuracy.
Element Length: 4
should be set equal to twice the thickness of the coal seam This parameter is used to control the
minimum boundary element size that will be used at locations where narrow seams or pillars are
located. This ensures that a well-conditioned, readily solvable problem will be formulated.
Grid Spacing: 0.5
should be set to approximately one quarter of the seam thickness. This parameter is used to control
the minimum boundary element size and the minimum spacing on the grid plane that will be used at
locations where it passes close to or intersects the model. Accurate results can be obtained as
close as half this spacing from the model surfaces. This parameter also ensures that a sufficient
number of stress points will be calculated within in the pillar to generate smooth contours.
The user is free to select a larger value for the grid spacing. This will result in smaller problem size
and hence shorter run times. However, with larger boundary elements results will be less accurate,
especially near the model surfaces, also with wider grid spacing, smooth contours cannot be
generated.
Suggested values for the discretization and lumping parameters are as follows:
DON=0.5, DOL=DOC=1, DOE=DOG=2 for 10-20% error
DON=0.5, DOL=DOC=2, DOE=DOG=4 for 5-10% error
DON=1.0, DOL=DOC=4, DOE=DOG=8 for < 5% error
Coarse analysis results are recommended for all problems except those where increased accuracy
is required. At this setting numerical errors of 10-20% in stress predictions can be expected. The
settings for detailed analysis results provide 5-10% numerical error. The settings for high accuracy
results provide less than 5% numerical error. The user is free to specify higher accuracy settings
for these parameters, however this will result in larger problem size and hence longer run times.
Running a Map3D Analysis
At this point we have completed construction of the model and are ready to begin an analysis. If
you are using Map3D Fault-Slip you will obtain an elastic solution to this problem. If you are using
Map3D Non-Linear, a complete non-linear analysis will be conducted.
Analysis is executed from the main menu.