I. Technical description The present manual describe the operation principle and functionality of electrical boiler controller, managing nominal capacities of up to 60kW, providing general control of the parameters of one water heating installation in relation to environment conditions. 1. Operation The Controller regulates the water heating system by affecting to the following components: Electrical heating elements and Circulation pump In fact the main principle of the operation is based on a regulation of the capacity of the heating elements in relation to the temperature in the heated premises (rooms). The control is provided by step regulation of the heating element capacity of 2 kW (respectively 4 kW when the capacity is bigger than 30 kW) by means of changing the number of switched on heating sections. The controller is consisted of: Basic control module (electrical boiler module) that is equipped with built-in weekly programmer and boiler regulator. The boiler module can operate independently without room thermo regulator. Module for temperature measurement and assignation in the heated premises that in fact is a room thermo regulator with or without outer weekly programmer. The Boiler Controller operates as a proportional capacity regulator in compliance with the temperature. In fact that allows using that part of the installed capacity, necessary for keeping the desired temperature level without over-expenditure of the electrical energy surplus. The previous mentioned principle avoids any water temperature fluctuations in the electrical boiler during the fixed operation regime that extends the life expectancy of the water heating components and increases its safety. 2. Regulation and signalization 2.1 Front panel – figure 1. - The front panel is a LCD display with a resolution of 128x64 (position 1) а) days of the week are indicated in this field, as the current one is underlined. The same field is being used to show control indications about emergency situations or about OFF regime; б) Present time. The same field is being used to indicate the start of the periods /operation and stop/ of the boiler during setting of the weekly program; в) Menu; г) Current operation capacity of the boiler; д) Поле за изобразяване на икони: - switched on circulation pump (1); - switched on electrical heating elements (2); - activated OFF regime (3); - overheating thermostat (4); - low water level in the boiler body (5); - the boiler body temperature water is bellow 15°С (6). tel.:00359 596 333 66 ||| fax:00359 596 325 80 ||| info@intiel.com ||| www.intiel.com 9 Peter Beron Str, Pomorie 8000, Bulgaria 2