Download AC Servo Drive

Transcript
PRONET series User’s Manual V. 1.04
Pa.
No.
Pn115
Name
Need
Repower
on
effective
control
mode
Function and meaning
Torque
feed
forward
filtering
No need
P,S
Mechanical impaction caused by smooth torque
feed forward . Unit:0.1ms
Pn116
P/PI switch
conditions
Need
P,S
0: torque instruction percentage
1: offset counter value
2: setting acceleration value
3: setting speed value
4: fixed PI
Pn117
Torque
switch
threshold
No need
P,S
The torque threshold value unit from PI control to
P control:%
Pn118
Offset
counter
switch
threshold
No need
P
The offset counter threshold value unit from PI
control to P :Pulse
Pn119
Setting
acceleratio
n
switch
threshold
No need
P,S
The acceleration threshold value unit from PI
control to P :10rpm/s
Pn120
Setting
speed
switch
threshold
No need
P,S
Pn121
Gain
switch
condition
The speed threshold value unit from PI control to
P:rpm
No need
P,S
0: Fixed to the first group gain
1: Outside power switch gain transfer(G-SEL)
2: Torque percentage
3: Offset counter value
4: Setting acceleration value(10r/min)
5: Setting speed value
6: there are position instructions input
Pn122
switch
delay time
No need
P,S
How long should the gain switch be delayed when
it get to the switch condition.
Pn123
Switch
threshold
level
No need
P,S
Gain switch’s trigger level
Pn124
Reserved
Pn125
Position
gain switch
time
No need
P
It can bridge smoothly by the parameter if the
change between the two groups’ gain is too large.
Pn126
Hysterics s
No need
P,S
It is used to set gain switch movement delay
-71-