Download NightView User`s Guide - Version 7.5
Transcript
Command-Line Interface step 6 Execute one line, stepping into procedures. step [/one | /all] [repeat] Abbreviation: s repeat The repeat argument specifies the number of lines to single step. The default is one line. /one This option causes only the current thread to resume execution. It has no effect on any other threads. When applied to a CUDA context, multiple threads will execute, possibly including all CUDA code. See “set-run-mode” on page 6-129 and “CUDA Debugging” on page 3-45. If both this option and /all are omitted, the current run mode controls which threads execute (see “set-run-mode” on page 6-129). This option is redundant for single-threaded processes. /all This option causes all threads in the process to resume execution. If both this option and /one are omitted, the current run mode controls which threads execute (see “set-run-mode” on page 6-129). This option is redundant for single-threaded processes. It is worth noting that the /all option does not imply that all threads will single step. All threads will execute while the current thread steps and then all threads will be stopped when the step operation completes. The other threads may execute many source lines or only a few instructions. step causes the processes specified by the qualifier to continue execution until they have crossed a source line boundary. With a repeat count, this happens repeat times. step follows execution into called procedures. That is, if the current line is a procedure call, and you step, then the process will execute until it is in that new procedure and then stop. If you want to step over the procedure, use next. See “next” on page 6-134. If a step command causes execution to enter or leave a called procedure, then the output includes the equivalent of a frame 0 command to show this. See “frame” on page 6-145. This command completes only when all of the processes specified by the qualifier have completed the single step or stopped for some other reason (like receiving a signal). See “Signals” on page 3-16 for a discussion of the interactions between single-stepping and signals. step is interpreted relative to the current frame. See “Current Frame” on page 3-27. That is, any lower frames are automatically finished before stepping. There are also commands to single step individual instructions. See “stepi” on page 6-136 6-133
Related documents
NightView User`s Guide - Concurrent Software Portal
Samson Q5 Specifications
NightView User`s Guide - Version 6.1
NightView User`s Guide - Concurrent Software Portal
Samson 215 Specifications
C for AIX User's Guide
IPLONGATE User's Guide
GNATforLEON / ORK+ User Manual - dit/UPM
Vision & Mission & Objectives ACCULAB
Samson S.curve 231 Musical Toy Instrument User Manual
READ ME BEFORE INSTALLING THIS PRODUCT READ ME
IPLONGATE Benutzerhandbuch