An intelligent weight controller using Profibus
•
~
ELLIFf)
To meet the requirements of TSR ~ 10 ms and TENC ~ 2.5 ms, the bit rate should be at
least 1.5 kbit/s for this system, and the encoder should be polled after 8 other slaves,
thus n=8. Tables with the calculated timing parameters, produced with Excel, can be
found in Appendix B.
3.4
Profibus-DP
Since we are using decentralised peripherals in the fruit grading system, the ProfibusDP protocol seems a logical choice. It supports the highest bit rate of 12 Mbit/s and
has several predefined services or service access points (SAPs):
• Default
Data exchange
• SAP54
Master-Master communication
• SAP55
Change station address
• SAP56
Read inputs
• SAP5?
Read outputs
• SAP58
Control commands to a DP slave
• SAP59
Read configuration
• SAP60
Read diagnostic information
• SAP61
Transmit parameters
• SAP62
Check configuration
All these SAPS have predefined frame structures, which allows the use of any
Profibus-DP slave from any manufacturer in the fruit grading system.
However, communications with the slaves still take place on a cyclic basis. In
paragraph 3.3.3 we stated that it would be convenient to use a Poll List that contains
the encoder device more than once to guarantee accurate timing. This is impossible in
Profibus-DP. In future, some a-cyclic extensions will be added to the DP standard,
referred to as DPE. As it is not a standard yet, only a few manufacturers support this
feature for the master stations, resulting in astronomical prices. Furthermore, the
solutions that are provided by these manufacturers are not quite elegant. For this
reason, the first version of the fruit grading system will use the FDL layer directly.
Future updates of the Profibus devices will support a-cyclic Profibus-DP.
19