Functional Deviations
2
Functional Deviations
ADC_XC8.003 Limitation during power-down mode
When the device enters power-down mode, the ADC power-down control level shifter
will experience an overstress condition. This overstress condition may cause the ADC
power-down control level shifter to fail, resulting the ADC module in entering powerdown mode permanently. Therefore, it is advisable to avoid using power-down mode.
Workaround:
None.
BROM_XC8.006 IRAM data corrupted after hardware reset
After the hardware reset, boot up via User Mode (MBC=1) affects certain IRAM data.
The affected IRAM address range:
(1) 00H - 07H
(2) 61H - 64H
(3) 80H - BFH
Workaround:
None
BROM_XC8.008
MCAN Bootstrap Loader functionality not available.
The functionality of the MCAN Bootstrap loader is not implemented.
Workaround:
None