Download User Manual
Transcript
DO NOT CONNECT AS WELL laser printer, labelling machines, copy machines, generators, vacuum cleaners, drain pumps, microwave ovens or other larger electric appliances to the output connectors. The electricity consumption would cause an overload and possibly even the damage of the UPS. To reduce the risk of overheating: do not cover or block the vent of the UPS unit, do not expose the appliance to direct sunlight, do not install it near heat emitting appliances such as space heaters or furnaces/ovens. Pull the mains plug out of the socket before cleaning. Do not use liquid or spray detergents. Do not expose the batteries to fire because they may explode. Do not open and/or damage the batteries on their outside: released electrolyte (lead-acid-accumulator) is harmful to skin and eyes. It may be toxic. A battery holds the risk of electric shocks and short circuits. The following precautions should be considered when working with batteries: 1) Remove watches, rings or other metal objects from your hands. 2) Use tools with insulated handles. 3) Wear rubber gloves and rubber boots. 4) Do not deposit tools and/or metal parts on the battery. 5) Disconnect the appliance from the mains each time you are connecting or disconnecting the battery terminals. The maintenance of the batteries should be executed by battery-knowledgeable personnel. Observe the recommended and necessary precautions. Keep unauthorised personnel away from the batteries. When the batteries are replaced, utilize the same quantity and type of sealed lead-acid battery. The ambient temperature may not exceed 40°C. For maintaining the battery lifetime, we advise an ambient operating temperature of 20°C to 25°C. Ensure during the installation of the appliance, that the sum of the residual current of the UPS and of the connected load does not exceed 3.5mA. Caution of electric shocks. Even when the unit is disconnected from the mains, dangerous voltages could be achieved via power supply from the battery. For that raison, interrupt the battery on its plus and minus poles when maintenance and servicing activities are necessary and undertaken. The mains socket outlet that supplies the UPS shall be installed near the UPS unit and shall be easily accessible. 3. SPECIFICATIONS LED Model BP650 BP850 BP1100 BP1300 BP1600 BP2200 & LCD Model BP650D BP850D BP1100D BP1300D BP1600D BP2200D 650VA 850VA 1100VA 1300VA 1600VA 2200VA Capacity Input Voltage Voltage range Frequency range Output Voltage in battery mode Frequency in battery mode Transfer time Batteries Recharge time Number and type of battery LED Indicator Mains mode (AC) Battery-Modus Protection Overvoltage / overload Audible alarm Battery mode Weak autonomy Overload Replace batteries Fault Size ratio Dimensions – mm (W x D x H) Net weight – kg Operating environment Ambient temperature Operating humidity 3 220 / 230 / 240 Vac 162-290 Vac 60/50 Hz (automatic recognition) 230 Vac ±10% (no block sinus) 50/60 Hz ±1% typically : 2 à 6 ms 1 x 12V7Ah 6-8 hours to reach 90% of capacity 1 x 12V9Ah 2 x 12V7Ah 2 x 12V7Ah 2 x 12V9Ah 2 x 12V9Ah green LED lighting green and orange LED lighting surge protection sounding every 10s sounding every 1s sounding every 0.5s sounding every 2s continuously sounding 101 x 298 x 142 4.25 4.9 149.3 x 338 x 162 7.8 8 158 x 380 x 198 11.1 11.5 0°C à 40°C < 90% without condensation BUDGET PRO series 650-2200VA - UPS www.visionups.com