Download data sheet - ABACOM Technologies
Transcript
POWER-SONIC Rechargeable Batteries Proper battery selection for a specific application can be made from this graph if the required time and current are known. For example, to determine the proper capacity of a battery providing 3 amps for 20 minutes, locate the intersection of these values on the graph. The line immediately above that point represents the battery which will meet the requirement. Figure 3: Capacity lines for Power-Sonic batteries Discharge Time (Amps) Figure 3 shows capacity lines for major Power-Sonic battery models with different ampere-hour ratings. Amperage is on the horizontal scale and the time elapsed is on the vertical scale; the product of these values is the capacity. Discharge Time (hrs)