Download Essence Installation Guide
Transcript
ESSENCE® Installation Checklist Did a structural engineer approve the mounting structure? See page 7 for Big Ass Fans-approved mounting structures. Are you familiar with the function and use of the safety cable? See pages 21–22 for information on properly securing the safety cable. Will the fan be installed so that the airfoils are at least 10 ft (3.05 m) above the floor? Will the fan be installed so that the airfoils have at least 2 ft (0.61 m) of clearance from obstructions? Will the fan be installed so that it is not subjected to high winds such as from a Heating, Ventilating, and Air Conditioning (HVAC) system or near a large garage door? If the fan is mounted at the same level or higher than a diffuser, the winglets or airfoil tips must be at a distance that is at least 1x the measure of the fan’s diameter. If the fan is mounted at the same height or below a diffuser, the winglets or airfoil tips must be at a distance that is at least 2x the measure of the fan’s diameter. Will the distance between multiple fans be at least 2.5x the fans’ diameter when measured from the centers of the fans? If you ordered multiple fans, did you keep the parts of each fan together? Customer Service: 1-877-BIG-FANS (International: +1 859 233 1271) WWW.BIGASSFANS.COM ©2013 DELTA T CORP. ALL RIGHTS RESERVED