Download Data Centre for High Performance Computing
Transcript
doors supplied should be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory.) 4.3 Measurement Doors shall be measured by outer actual size of the assembly including the sub frame if any specified. Measurement shall be Inclusive of all fixtures, Fastenings, glass, gasket, sealing along the external jams with sealant. 5. PAINTING 5.1 LUSTER PAINT Providing and applying Luster of approved make and shade on all surfaces at all heights in three coats including scaffolding, preparing the surface by brushing and brooming down, applying primer two coats and final luster paint applying and leveling the surface with coat of Birla white putty before and after the primer coat and also after the first coat etc. complete. The dry/wet cleaning of floors/pipes/glass etc. after painting is to be carried out; protection of surfaces before painting is included in the item. 5.2 Materials: Glossy, Flat, Pearl Luster and Matt enamel paint shall conform to IS : 1932-1964 and M-44B. 5.3 Workmanship : The materials required for work of painting work shall be obtained directly from approved manufacturers or approved dealer and brought to the site in maker's drums, cage etc. with seal unbroken. All materials not in actual use shall be kept properly protected, lid of containers shall be kept closed and surface of paint in open or partially open containers covered with a thin layer of turpentine to prevent formation of skin. The materials which have become stale or flat due to improper and long storage shall not be used. The paint shall be stirred thoroughly in its container before pouring into small containers. While applying also, the paint shall be continuously stirred in smaller container. No left over paint shall be put back into stock tins when not in use. The paint shall be stirred thoroughly in its container before pouring into small containers. If for any reasons, thinning is necessary, the brand of thinner recommended by the manufacturer shall be used. The surface to be painted shall be thoroughly cleaned and dusted. All rust, dirt and grease shall be thoroughly removed before painting is started. No painting on exterior or other exposed IITM’s HPC DATA CENTER RFP Page 358 of 572
Related documents
VIA30P Installation Instructions
Liebert® eXL™ Uninterruptible Power System
manual técnico de aplicações sanitárias e de aquecimento
DIVISION 16 - ELECTRICAL PAGES Section 16000: Electrical
Tender Document
SDI7984P16
Anexo XVII- LOTE 01
HOME - INSPECTION sarl Rapport d`Inspection PRÉ
ARIA ITALIANO
GPPC - GSPC
608DA07_relazione elettrica R01
TLB 425T User Manual/IFU