Download Single Qubit Bootstrapping and Gate Calibration
Transcript
Prepare
states {ρi}
Result
states {ρf}
Quantum
Process
Reconstruct
{ρi} , {ρf}
State
Tomography
Use {ρi} , {ρf} to calculate χ
Figure 17: Calculating χ
I
σx
σy
σx
σz
σy
σz
I
I
σx
σy
σx
σz
σy
σz
I
Figure 18: Quantum Process Tomography - Real part of the χ-matrix for
single-quadrature Gaussian (left) and HD (right) in the Pauli {I, σx , σy , σz }
basis. The only ideal matrix component is the σx , σx component. Notice
how HD corrects for the σz , σx error process. Imaginary components of the
χ-matrix not shown as error elements are small and not strongly effected by
HD.
5
Flux Bias Calibration: Z control
Up through this point, we have high fidelity control for any X or Y gate,
as well as any combination of the two. However, what has gone completely
untouched is Z control. Fortunately, once the microwaves are tuned up this
becomes relatively straightforward. The Z control works by changing the relative phase between the |0i and |1i state, but does not excite any transitions
between them. The challenge in tuning up Z gates is that to read out the
qubit we measure P1 . Since Z gates do no directly effect this value, we must
19