Download FSP 150SP-100 R6.1.1..

Transcript
Condition Type
Link Down - Cable
Removed
Link Down Auto-Negotiation
Failed
Link Down
Installation and Operations Manual
Link Down Master Slave
Config
Description /
Probable Cause
Link Down is generated when a
physical connection is lost on a good
link on the Ethernet interface port
(Access or Network). A Cable
Removed notification is sent when it is
determined that the link is down due to
a cable being locally removed from its
RJ-45 port connection.
Link Down is generated when a
physical connection is lost on a good
link on the Ethernet interface port
(Access or Network). Auto negotiation
fault indicates the Far End is not
advertising its auto negotiation rate.
Link Down is generated when a
physical connection is lost on a good
link on the Ethernet interface port
(Access or Network).
Link Down Master Slave Configuration.
Trouble Clearing Procedure
NSA Default
Notification
SA Default
Notification
LED
Indication
Insert or repair cable.
Facility
Red
Minor
Critical
Link/Rate
Off
Test and repair far end
equipment.
Facility
Red
Minor
Critical
Link/Rate
Off
Perform an Etherjack
Diagnostic test. Repair the port
using test results.
Facility
Red
Minor
Critical
Link/Rate
Off
Facility
Red
Verify Master Slave
configuration.
Minor
Critical
Link/Rate
Off
Receiving Jabber
The total number of packets received
were longer than the MTU size, and
had either a bad Frame Check
Sequence (FCS) with an integral
number of octets (FCS Error), or a bad
FCS with a non-integral number of
octets (Alignment Error).
Verify the signal leaving the far
end NID, through any intermediate equipment, and at the
near end. Probable Cause:
Network problem, or possibly a
bad cable. Repair faulty
equipment or cable.
FSP 150SP-100 R6.1.1 80000026364 Issue: A, © 2014 ADVA Optical Networking SE - Confidential
Minor
Major
Facility
Red
Alarm Attributes, Probable Cause and Trouble Clearing
418
Table 31: Network Port and Access Port Alarms (Continued)